Cabinet DimensionsA. 15" (38.1 cm) on 15" (38.1 cm) models," 30" (76.2 cm) on30" (76.2 cm) models; 36" (91.4 cm) on 36" (91.4 cm) modelsB. Combustible area above countertep (shown by dashed box above)C. 30" (76.2 cm) minimum clearance between top of coektop platformand bottom of unprotected wood or metal cabinet (24" [61 cm]minimum clearance if bottom of wood or me tal cabinet is protectedby not less than V4"[0.6 cm] flame retardant mlllboard covered withnot less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainlesssteel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)D. 13" (33 cm) recommended upper cabinet depthE. 2" (5.1cm)F. 20F2" (52 cm)G. 18" (45.7 cm) minimum clearance from upper cabinet to countertopwithin minimum horizontal clearances to cooktopH. Junction box or outlet; 12" (30.5 cm) minimum from bottom ofcountertopI. Junction box or outlet; 10" (25.4 cm) from right side of cabinetJ. 14F2" (36.8 cm) on 15" (38.1 cm) models; 29Fp" (74.9 cm) on30" (76.2 cm) models; 35F2" (90.2 cm) on 36" (91.4 cm) modelsK. 1" (2.5 cm) minimum distance to nearest left and right sidecombustible surface above cooktopL. 1F_" (3.8 cm) max. counter thickness on 15" (38.1 cm) models. Seefollowing illustration.M. 1" (2.5 cm) minimum clearance between back wall and countertopNOTES: After making the countertop cutout, some installationsmay require notching down the base cabinet side walls to clearthe cooktop base. To avoid this modification, use a base cabinetwith sidewalls wider than the cutout.If cabinet has a drawer, a 3" (7.6 cm) depth clearance from thecountertop to the top of the drawer (or other obstruction) in basecabinet is required.If installing a hood above the cooktop, follow hood instructions fordimensional clearances above the cooktop surface.For model 15" (38.1 cm) model only:rear of cabinet orrear wall undercountertopback edgeof cutoutBA. W,6" (1.7cm) min.B. IF±" (3.8 cm) max.For 15" (38.1 cm) model only:Electrical Shock HazardDisconnect power before servicing.Use 12 gauge copper wire.Electrically ground cooktop.Failure to follow these instructions can result in death,fire, or electrical shock.For all models except 15" (38.1 cm) modelElectrical Shock HazardDisconnect power before servicing.Use 8 gauge copper wire.Electrically ground cooktop.Failure to follow these instructions can result in death,fire, or electrical shock.If codes permit and a separate ground wire is used, it isrecommended that a qualified electrical installer determine thatthe ground path and wire gauge are in accordance with localcodes.