For 15" (38.1 cm) model only:Electrical Shock HazardDisconnect power before servicing.Use 12 gauge copper wire.Electrically ground cooktop.Failure to follow these instructions can result in death,fire, or electrical shock.For all models except 15" (38.1 cm) model:Electrical Shock HazardDisconnect power before servicing.Use 8 gauge copper wire.Electrically ground cooktop.Failure to follow these instructions can result in death,fire, or electrical shock.This cooktop is manufactured with a frame connected, green orbare ground wire. Connect the cooktop cable to the junction boxthrough the UL listed or CSA approved conduit connector.1. Disconnect power.2. Remove junction box cover, if present.3. Connect the flexible cable conduit from the cooktop to thejunction box using a UL listed or CSA approved conduitconnector.4. Tighten screws on conduit connector if present.5. See "Electrical Connection Options Chart" to completeinstallation for your type of electrical connection.Electrical Connection Options ChartFor cooktops with a 4-wire cable:If your home has: If your cooktop has: Go to Section:4-wire 4-wire 4-Wire Cablefrom Homei Power Supply to4-Wire Cable(1_3cm) from Cooktop4-Wire Cablefrom HomePower Supply to3-Wire Cablefrom CooktopFor cooktops with a 3-wire cable:3-wire 4-wire 3-Wire Cablefrom HomePower Supply to4-Wire Cable(1_3cm) from Cooktop3-wire 3-Wire Cablefrom HomePower Supply to3-Wire Cablefrom Cooktop