17INsTaLLaTIONIdeal Logic Code Combi - Installation and ServicingFLUE OUTLETNotes.1. It is recommended that a support bracketis fitted for every 1 metre of extension pipeused and a bracket should be used at everyjoint, to ensure pipes are held at the correctangle.If a slip joint coupling is to be used then abracket should be used to secure the collar.2. When extension ‘D’ packs are used the flueduct MUST be inclined at 1.5 degrees tothe horizontal to allow condensate to drainback into the boiler and out through thecondensate drain.3. If the B pack, or telescopic B pack only areused, they may be mounted horizontally.The 1.5 degrees is taken care of by theinclination of the flue within the air pipe.4. Only use water as a lubricant duringassembly.11 DETERMININg ThE FLUE LENgTh aND FLUE paCKs REqUIRED CONT’D12 FLUE assEMBLy - Exploded ViewAn optional flue duct extensionkit is required for wallthicknesses greater than :side 378mmRear 420mmtelescopic b Pack shownLEgEND1. Duct assembly.2. Flue turret.3. Turret clamp.The flue terminal MUSTbe fitted with the ‘TOP’uppermost to allow thecorrect fit and use ofthe plume managementsystem.TOPTotal Flue Length Dimension(measuring from CL of Turret to outside wall)FlueRear flue dim.x+155Side flue dim.L+197Extra packsrequiredBoiler SizeUp to 640 mm Up to 640 mm none 26, 33 & 38Up to 1590 mm Up to 1590 mm Pack D - 1 off 26, 33 & 38Up to 2540 mm Up to 2540 mm Pack D - 2 off 26, 33 & 38Up to 3490 mm Up to 3490 mm Pack D - 3 off 26, 33 & 38Up to 4440 mm Up to 4440 mm Pack D - 4 off 26, 33 & 38Up to 5390 mm Up to 5390 mm Pack D - 5 off 26, 33 & 38Up to 6340 mm Up to 6340 mm Pack D - 6 off 26, 33 & 38*Up to 7290 mm Up to 7290 mm Pack D - 7off 26 & 33Up to 8240 mm Up to 8240 mm Pack D - 8 off 26 & 33**Up to 9000 mm Up to 9000 mm Pack D - 9 off 26Total Flue Length Dimension(measuring from CL of Turret to outside wall)FlueRear flue dim.x+155Side flue dim.L+197Extra packsrequiredBoiler SizeUp to 575 mm Up to 575 mm none 26, 33, & 38Up to 1525 mm Up to 1525 mm Pack D - 1 off 26, 33, & 38Up to 2475 mm Up to 2475 mm Pack D - 2 off 26, 33, & 38Up to 3425 mm Up to 3425 mm Pack D - 3 off 26, 33, & 38Up to 4375 mm Up to 4375 mm Pack D - 4 off 26, 33, & 38Up to 5325 mm Up to 5325 mm Pack D - 5 off 26, 33, & 38Up to 6275 mm Up to 6275 mm Pack D - 6 off 26, 33, & 38*Up to 7225 mm Up to 7225 mm Pack D - 7 off 26 & 33Up to 8175 mm Up to 8175 mm Pack D - 8 off 26 & 33**Up to 9000 mm Up to 9000 mm Pack D - 9 off 26*Logic Code Combi 38 is capable of 6m flue only** Logic Code Combi 33 is capable of 8m flue only*Logic Code Combi 38 is capable of 6m flue only** Logic Code Combi 33 is capable of 8m flue onlyTELEsCOpIC FLUENON - TELEsCOpIC FLUE206279-10257213