AM-800CL / AB-800CL- 23 -6.2.1.2 AOI settingLVALFVALDVALDATAEENXEENCCDExpsoureValid dataA B C3LFig.20 Vertical timing for partial scanning (AOI)Frame rate examples when the start line and the end line are set as followsOffset HEGHT A(L)B(L)C(L)Total line(L)Frame rate(Hz)618 1236 181 618 0 799 26.89927 618 258 309 0 567 37.89309 618 104 618 78 800 26.85463 309 142 309 116 567 37.896.2.2 If the binning control is BNC=1(1x2) or BNC=3(2x2)6.2.2.1 AOI initial setting (Offset=0, Height=2472)LVALFVALDVALDATAEENXEENCCD ExposureValid Data3L 18L 618L Frame rate: 639L, 30.96fpsFig.21 Vertical timing for the vertical binning