AM-800CL / AB-800CL- 45 -9.3. Save and load functionsThe following commands are for storing and loading camera settings in the camera EEPROM.Load settings. LD.This command will load previously stored settings to the camera. 3 user settings can be stored inthe camera EEPROM. 1 factory setting is also stored in the camera. The settings stored in the lastused user area are used as default settings at power up.Save Settings. SA.This command will store the actual camera settings to 1 of the 3 user areas in the camera EEPROM.EEPROM Area. EA.If received, the camera will return the last used user area number.9.4 Command listCommandName Format Parameter RemarksA - General settings and utility commands.1 Camera StatusRequest ST? Actual setting2 Online HelpRequest HP? Command list3 FirmwareVersion VN?3 digits(e.g) 100 = Version1.004 Camera IDRequest ID? max 12 characters5 Model NameRequest MD? max 12 characters6 User ID UD=[Param.]UD?User can save andload free text.(12 orless characters)7 Error codeERRER=[Param.]>ERRER?One of following values will be repliedfrom the camera0=One-Push has not been finished yet.1=Succeeded.2=Error1. Green image was too bright.3=Error2. Green image was too dark.4=Error3. Timeout-error occurred.B – Image format control1 Height ETL=[Param.]ETL? SC=1: :2 to 2472 AB-800:2Line stepAM-800:1Line step2 Offset Y STL=[Param.]STL? SC=1: :1 to 2471 AB-800:2Line stepAM-800:1Line step3 Binning Vertical BNC=[Param.] 0=off Only AM-800CL