AM-800CL / AB-800CL- 30 -7.3.3 Trigger Overlap (Command: TO)This function sets if a trigger pulse can be accepted while data is being read out or not.TO=0 OFF : The trigger pulse is not accepted during CCD readout.This works the same as the LVAL asynchronous mode.TO=1 Read Out : The trigger pulse can be accepted during CCD readout.If the trigger pulse is input during CCD readout, it operates as LVALsynchronous and if the trigger is input while the CCD is not beingread out, it operates as LVAL asynchronous.7.3.4 Trigger Dump (Command: TD)The trigger edge dump has TD=0(disable) and TD=1(enable) modes.This command can be used with EM=1 (Timed) and it operates the same as RCT mode.If this mode is “enabled”:Until the trigger is input, the camera operates continuously and the video signal for theauto-iris lens is output. When the trigger is input, the fast dump is activated to read outthe electronic charge very quickly, after which the accumulation and the readout areperformed. When the signal is read out, FVAL , LVAL and DVAL are output too.7.4. Auto shutter control (Commands: ASC,ASCS,ASCEA,ASCEI)This turns the auto exposure function “ON” or “OFF” and provides settings for variousparameters.ASC=0 (OFF), ASC=1 (ON)ASCS: ASC tracking speed setting. Range is from 1 to 16 (Default is 8).ASCEA: Maximum exposure time in the ASC mode. Range is from 10 to 1048575 (μs).ASCEI: Minimum exposure time in the ASC mode. Range is from 10 to 1048575 (μs).This function is available on the continuous operation and trigger-dump ON.