Testing Procedures! WARNINGTo avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,unless testing requires power and/or gas.© 2006 Maytag Services 16026929 21Feature Access Procedure Modification Procedure208/240 V SettingDetermines range operatingvoltage (208 or 240 VDC).Press the Setup pad, then press the rightATM pad until 208/240 displays. Press theleft ATM pad to select 208/240 V settings.Press the left ATM pad to select 208 VDC, or theright ATM pad to select 240 VDC. Press Setup toexit.Cook TonesDetermines the number andduration of cook time reminderchimes.Press the Setup pad, then press the rightATM pad until TONES displays. Press theleft ATM pad. Press the left ATM pad againto select COOK TONES settings.Press the left ATM pad to select 1 – 30 (1 chimeevery 30 seconds after the initial 4 chimes), orpress the right ATM pad to scroll to 1 – 60 (1 chimeevery 60 seconds after the initial 4 chimes) or 1BEEP (no additional chimes after the initial 4chimes). Press the left ATM pad to select thedesired setting. Press Setup to exit.Timers TonesDetermines the number andduration of timer reminderchimes.Press the Setup pad, then press the rightATM pad until TONES displays. Press theleft ATM pad. Press the right ATM pad toscroll to TIMERS TONES. Press the left ATMpad to select TIMERS TONES settings.Press the left ATM pad to select 2 – 30, or 2chimes every 30 seconds for up to 5 minutes (afterthe initial chime), or press the right ATM pad toscroll to 2 – 60, or 2 chimes every 60 seconds forup to 30 minutes (after the initial chime), or 1 BEEP(no additional chimes after the initial chime). Pressthe left ATM pad to select the desired setting.Press Setup to exit.VolumeDetermines volumes of cookand timer tones.Press the Setup pad, then press the rightATM pad until TONES displays. Press theleft ATM pad to select VOLUME settings.Press the right ATM pad until VOLUME displays.Press the left ATM pad. Press the left ATM pad toselect HIGH, or the right ATM pad to scroll toMEDIUM or LOW. Press the left ATM pad to selectdesired setting. Press Setup to exit.Energy Saver ModeEnables a 1 watt standbyfeature. If no pad is pressedwithin 5 minutes, the controlenters a sleep mode.Press the Setup pad, then press the rightATM pad until ENERGY SAVER displays.Press the left ATM pad to select ENERGYSAVER mode settings.Press the left ATM pad to enter the energy savermode or the right ATM pad to exit the energy savermode. Press Setup to exit.Demo ModeEnables a 1 watt standbyfeature. If no pad is pressedwithin 5 minutes, the controlenters into a sleep mode.Press the Setup pad, then press the rightATM pad until DEMO displays. Press the leftATM pad to select DEMO mode settings.Press the left ATM pad to enable the DEMO modeor the right ATM pad to exit the DEMO mode.Once the DEMO mode begins, press any key toexit. Press Setup to exit, also.Service ModeEnables access to servicemenus.Press the Setup pad, then press the rightATM pad until SERVICE displays. Press theleft ATM pad to select SERVICE menuoptions.Press and hold the Back and Enter pads for 5seconds to enter SERVICE menu options. PressSetup to exit.Test AccessEnables access to servicemenus.Press the Setup pad, then press the rightATM pad until SERVICE displays. Press theleft ATM pad to select SERVICE menuoptions.Press and hold the Back and Enter pads for 5seconds to enter SERVICE menu options. Pressthe right ATM pad to scroll to TEST menu. Pressthe left ATM pad to select TEST options. PressSetup to exit.Faults AccessDisplays the 10 most recentfaults produced by thecontroller.Press the Setup pad, then press the rightATM pad until SERVICE displays. Press theleft ATM pad to select SERVICE menuoptions.Press and hold the Back and Enter pads for 5seconds to enter SERVICE menu options. Pressthe right ATM pad to scroll to the FAULTS menu.Press the left ATM pad to select FAULTS options.Press Setup to exit.Software Versions AccessDisplays the software andEEPROM revision levels.Press the Setup pad, then press the rightATM pad until SERVICE displays. Press theleft ATM pad to select SERVICE menuoptions.Press and hold the Back and Enter pads for 5seconds to enter SERVICE menu options. Pressthe right ATM pad to scroll to the VERSIONSmenu. Press the left ATM pad to view. PressSetup to exit.Display TestIlluminates all lamps on thecontrol.Press the Setup pad, then press the rightATM pad until SERVICE displays. Press theleft ATM pad to select SERVICE menuoptions.Press and hold the Back and Enter pads for 5seconds to enter SERVICE menu options. Pressthe right ATM pad to scroll to DISPLAY TEST.Press the left ATM pad. Press Setup to exit.Control LockoutDisables the keypad controland locks the oven cavity door.Press the Back and Setup padssimultaneously for 5 seconds to lock.Press the Back and Setup pads simultaneously for5 seconds to unlock.