© 2006 Maytag Services 16026929 27To avoid risk of electrical shock, personal injury ordeath; disconnect power and gas to range beforeservicing, unless testing requires power and/or gas.Disassembly ProceduresCooling Fan Replacement1. Remove power from unit.2. Remove range from installation position, see"Removing and Replacing Range" procedure.3. Remove back panel, see "Back Panel Removal"procedure.4. Label and disconnect wire terminals from cooling fan.5. Remove screws securing fan to range chassis.6. Reverse procedure to reinstall cooling fan.Hidden Bake Element Replacement(Select Models)1. Remove power from unit.2. Open oven door and remove rack(s).3. Remove screws securing hidden bake element cover.4. Remove hidden bake element cover by sliding covertoward the rear of the oven cavity while lifting up onfront of cover.5. Remove screws securing bake element to rear ofcavity wall.6. Pull element forward to allow for labeling anddisconnection of wire terminals.7. Remove element support clips.8. Reverse procedure to reinstall bake element.Bake Element Replacement (Select Models)1. Remove power from unit.2. Open oven door and remove rack(s).3. Remove screws securing bake element to rear ofcavity wall.4. Pull element forward to allow for labeling anddisconnection of wire terminals.5. Remove element support clips.6. Reverse procedure to reinstall bake element.Broil Element Replacement1. Remove power from unit.2. Open oven door and remove racks.3. Remove screws securing broil element to top andrear of oven cavity.4. Pull broil element forward to allow disconnection ofwiring from terminals.5. Reverse procedure to reinstall broil element.Downdraft Blower Motor Removal(Select Models)1. Remove power from unit.2. Remove bottom access panel, see "Bottom AccessPanel Removal" procedure.3. Disconnect ducting to allow for downdraft blowermotor removal.4. Label and disconnect wire terminals.5. Remove screws securing motor assembly.6. Reverse procedure to reinstall downdraft blowermotor (select models).Downdraftblower motorassemblyConvection Motor Removal1. Remove power from unit.2. Open oven door and remove rack(s).3. Remove screws securing convection element and fancover (on rear wall of oven cavity).4. Remove screw securing fan blade to fan motor shaft.5. Remove screws securing fan motor to cavity wall.6. Slide motor into oven cavity.7. Label and disconnect wire terminals from motor.8. Reverse procedure to reinstall convection motor.Convection Element Replacement1. Remove power from unit.2. Open oven door and remove rack(s).3. Remove screws securing convection element and fancover (on rear wall of oven cavity).4. Remove screw securing convection element to rearoven cavity wall.5. Label and disconnect wire terminals from element.6. Reverse procedure to reinstall convection element.