Testing Procedures! WARNINGTo avoid risk of electrical shock, personal injury or death; disconnect power range before servicing, unless testingrequires power.20 16026926 © 2006 Maytag ServicesSwitch Membrane Assembly Test Procedure ResultsJES9800BA*,JES9900BA*Closed circuitry resistance(defined as continuity): 2000 Max ΩPins 1 & 10 are shorted together for controlconfiguration purposesDetail BSee Detail BTrace # 1LatchPad1234567890CancelBakeBroilCleanConvectFavoritesRapid PreheatVent FanMore OptionsSetupATM 1ATM 2BackEnterTimer 1Timer 2Oven LightTrace2 & 72 & 82 & 92 & 102 & 112 & 123 & 63 & 73 & 82 & 64 & 94 & 104 & 115 & 75 & 94 & 125 & 105 & 115 & 85 & 64 & 64 & 73 & 93 & 103 & 113 & 124 & 8MeasurementContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityContinuityElectronic Oven Control (EOC) III Testing ProceduresWarmDrawerATM PADSELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURESFeature Access Procedure Modification ProcedureControl ResetResets control to factory defaultvalues.Press the Setup pad, then press the right ATMpad until SERVICE displays. Press the leftATM pad to select SERVICE menu options.Press and hold the Back and Enter padsfor 5 seconds to enter SERVICE menuoptions. Press the right ATM pad to scrollto CONTROL RESET. Press the left ATMpad to select CONTROL RESET, thenpress the left ATM pad again to reset thecontrol logic. Press Setup to exit.Oven Temperature AdjustmentDetermines oven cavity offsettemperature (range from -35° F to+35° F, or -21° C to +21° C).Press the Setup pad, then press the right ATMpad until TEMP ADJUST displays. Press theleft ATM pad to select oven TEMPADJUSTMENT settings.Enter the offset temperature setting desiredusing the digits pads. Press the right ATMpad for + temperature adjustment, or theleft ATM pad for – temperature adjustment.Press 0 to reset control back to notemperature adjustment. Wait 3 secondsfor the control to accept the request. PressSetup to exit.