TK-2312/23175REALIGNMENT4. Wireless Clone Mode4-1. Outline“Wireless Clone Mode” copies the transceiver data toanother transceiver.The dealer can copy the transceiver data to anothertransceiver even without the use of a personal computer.4-2. ExampleThe transceiver can copy the programming data to oneor more transceivers via RF communication.The clone source and clone target/s must be in wirelessclone mode.4-3. Operation1. To switch the clone target/s to Clone mode, press andhold the [ON.2. Wait for 2 seconds. “CLONE” appears on the LCD, fol-lowed by “FRQTBL 1”.3. Select a channel table number using the [Selector] knob.4. To switch the clone source to Clone mode, press andhold the [ON.5. Wait for 2 seconds. “CLONE” appears on the LCD, fol-lowed by “FRQTBL 1”.6. Select the same channel table number as the clone tar-get/s.7. Press the [S] key on the clone master to begin data trans-mission. When the clone target starts to receive data,the green LED will light and “CLONING” will appear onthe LCD. The source unit will display “MASTER”.8. When the clone source finishes sending data, a “confir-mation” tone will sound and “COMPLETE” will appearon the LCD. If data transmission failed while cloning, thetarget unit will produced an error tone and “CLONE NG”will appear on the LCD.9. If the cloning fails, no data will be available in the targetunit when it is returned to User mode.10.When the cloning is successful, the target unit's “Scan”and “Key lock” functions will return to their default val-ues (Scan = OFF, Key lock = OFF).11.The source will remain in clone mode after cloning. Thetarget unit will return to user mode after a successfulcloning.Note:• The dealer can clone data to two or more transceivers byrepeating the above procedures.• If the transceivers wireless clone Mode is configured as“Disabled”, the transceiver cannot enter Clone mode.• The table shown below will cover the frequency tablesused for wireless cloning.• Wireless clone mode cannot be entered in battery lowstate.• A unit cannot be a “Source Unit” if it is unprogrammed.If the [S] key is pressed, an “error” tone will sound.• Once a unit is set to be the source, it cannot be a targetafter the data has been transmitted. This protects thedata in the source unit.• MSK signaling is used in cloning.• Electronic interface may cause a failure in data transferduring Wireless Clone, such as when waveforms or elec-tromagnetics are being performed at the workbench.• Wireless clone mode can be used ONLY by the autho-rized service personnel.• The wireless clone mode setting must be configured as“Disable” before being delivered to the end-user.• To wireless clone, replace the antenna from both thesource transceiver and the target transceiver with adummy load.• The transmit output power is automatically set to Low inClone mode.4-4. Adding the Data PasswordIf the Data password is set to the transceiver, you mustenter the password to activate a clone mode. The maximumlength of the password is 6 digits.The following describes how to enter the password.1. Press and hold the [the transceiver power on.2. “CLN.LOCK.R”(When the Read authorization passwordis set to the transceiver.) / “CLN.LOCK.W” (When theOverwrite password is set to the transceiver.) is dis-played on the LCD.3. If the [selector] knob is rotated while “CLN.LOCK.R”/“CLN.LOCK.W” is displayed, the number (0 to 9) flasheson the LCD.When you press the [C>] key, the currently selectednumber is determined.If you press the [A] key, the least digit of the password isdeleted.If you press the [S] key after entering the password inthis procedure, “FRQTBL 1” is displayed if the enteredpassword is correct.If the password is incorrect, “CLN.LOCK.R”/ “CLN.LOCK.W” is redisplayed.• Clone frequency tableNo. Operating frequency 136~174 (MHz)1 136.0002 138.0003 140.0004 142.0005 144.0006 146.0007 148.0008 150.0009 152.00010 154.00011 156.00012 158.00013 160.00014 162.00015 164.00016 166.00017 168.00018 170.00019 172.00020 174.000