21ADJUSTMENTMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItemTK-4809. DQT BAL 1) SYS – GRP : 4 – ✽ Power meter Panel ANT Panel Encoder Make the demodu-adjustment Select BAL ✽ ✽ ✽ Deviation knob lation waves intoin tuning mode. meter square waves.Deviation meter filter setting OscilloscopeLPF : 3kHzHPF : OFF AGPTT : ON AF VTVM10. MAX DEV 1) SYS – GRP : 4 – ✽ Universal 3.8kHz ± 50Hzadjustment Select MAX ✽ ✽ ✽ (According to thein tuning mode. larger +, –.)AG : 1kHz/150mVDeviation meter filter settingLPF : 15kHzHPF : OFFAdjustment itemL MAX ✽ ✽ ✽ →C MAX ✽ ✽ ✽→H MAX ✽ ✽ ✽PTT : ON11. T/A MAX 1) SYS – GRP : 4 – ✽DEV Select TMAX ✽ ✽ ✽adjustment in tuning mode.AG : 1kHz/150mVDeviation meter filter settingLPF : 15kHzHPF : OFFAdjustment itemL TMAX ✽ ✽ ✽ →C TMAX ✽ ✽ ✽→H TMAX ✽ ✽ ✽PTT : ON12. NPSPAC 1) SYS – GRP : 10 – ✽ 2.9kHz ± 50HzMAX DEV Select NMAX ✽ ✽ ✽ (According to theadjustment in tuning mode. larger +, –.)AG : 1kHz/150mVDeviation meter filter settingLPF : 15kHzHPF : OFFAdjustment itemL NMAX ✽ ✽ ✽ →C NMAX ✽ ✽ ✽→H NMAX ✽ ✽ ✽PTT : ON13. MIC 1) SYS – GRP : 4 – 1 Check 2.2~3.6kHzsensitivity AG : 1kHz/15mVcheck Deviation meter filter settingLPF : 15kHzHPF : OFFPTT : ON14. T/A MIC 1) SYS – GRP : 4 – 1sensitivity TA mode : ONcheck (Press [A] key, then [C] key)AG : 1kHz/15mVDeviation meter filter settingLPF : 15kHzHPF : OFFPTT : ON