ADJUSTMENTMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItem22TK-48015. QT DEV 1) SYS – GRP : 4 – ✽ Power meter Panel ANT Panel Encoder 0.75kHz ± 0.05kHzadjustment MIC input : OFF Deviation knobSelect FQT ✽ ✽ ✽ meterin tuning mode. OscilloscopeDeviation meter filter settingLPF : 3kHz AGHPF : 50Hz AF VTVMDe-emphasis : 750μsPTT : ON16. DQT DEV 1) SYS – GRP : 4 – ✽adjustment Select FDQT ✽ ✽ ✽in tuning mode.Deviation meter filter settingLPF : 3kHzHPF : OFFPTT : ON17.LTR DEV 1) SYS – GRP : 4 – ✽ 1.00kHz ± 0.10kHzadjustment Select FLTR ✽ ✽ ✽in tuning mode.Deviation meter filter settingLPF : 3kHzHPF : OFFPTT : ON18. DTMF DEV 1) SYS – GRP : 4 – ✽ 3.00kHz ± 0.15kHzadjustment Select DTMF ✽ ✽ ✽in tuning mode.Deviation meter filter settingLPF : 15kHzHPF : OFFPTT : ON19. MSK DEV 1) SYS – GRP : 4 – ✽adjustment Select FMSK ✽ ✽ ✽in tuning mode.Deviation meter filter settingLPF : 15kHzHPF : OFFPTT : ON20. TONE DEV 1) SYS – GRP : 4 – ✽ 2.5kHz ± 0.1kHzadjustment Select TONE ✽ ✽ ✽in tuning mode.Deviation meter filter settingLPF : 15kHzHPF : OFFPTT : ON21. BATT 1) SYS – GRP : 4 – ✽ After pressing the BATT terminal voltage : 6.2Vdetection Select BATT ✽ ✽ ✽ PTT switch, confirmwriting in tuning mode. that one predeter-PTT : ON mined numeric inthe range 1 to 256appears and thenpress [B] key.That numeric will bestored in memory.