TK-5810 (BG) /5810H (BG)67ADJUSTMENTItemCondition Measurement Adjustment Specifications /RemarksPanel tuning mode PC test mode Test-equipment Unit Terminal Unit Parts Method8. MIC sensi-tivity check*31) Adj item: [MIC]Adjust: [129]Deviation meterLPF: 15kHzHPF: OFFDetector: ±PEAK/2AG: 1kHzPTT: ON1) Adj item: [Mic sen-sitivity]Deviation meterLPF: 15kHzHPF: OFFDetector: ±PEAK/22) Adj item: [129]AG: 1kHzPTT: Press [Trans-mit] button.DeviationmeterOscillo-scopeAGAF VTVMRearpanelANT [Paneltuningmode][PF3][PF4][PC testmode][ ],[ ]Adjust AG inputto get a standardMOD.5.0mV±1.5mV*3: The MIC sensitivity is related to the Max DEV adjustment. If the Max DEV has been adjusted correctly, the MIC sensitivity must be within 5mV ±1.5mV at adjustment digit “129”.9. QT FineDeviationwrite *4(Wide)1) Adj item: [QTW]Adjust: [✳✳✳]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: ONPress [PF5] key tostore the adjust-ment value.1) Adj item: [QT FineDeviation (Wide)]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: Press [Trans-mit] button.Press [OK] buttonto store the adjust-ment value.DeviationmeterOscilloscopeRearpanelANT [Paneltuningmode][PF3][PF4][PC testmode][ ],[ ]Write the value asfollowings.133 (Referencevalue)0.75kHz±50Hz(Narrow) 1) Adj item: [QTN]Adjust: [✳✳✳]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: ONPress [PF5] key tostore the adjust-ment value.1) Adj item: [QT FineDeviation (Narrow)]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: Press [Trans-mit] button.Press [OK] buttonto store the adjust-ment value.Write the value asfollowings.132 (Referencevalue)0.35kHz±25Hz10. DQT FineDeviationwrite *4(Wide)1) Adj item: [DQTW]Adjust: [✳✳✳]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: ONPress [PF5] key tostore the adjust-ment value.1) Adj item: [DQT FineDeviation (Wide)]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: Press [Trans-mit] button.Press [OK] buttonto store the adjust-ment value.Write the value asfollowings.101 (Referencevalue)0.75kHz±50Hz(Narrow) 1) Adj item: [DQTN]Adjust: [✳✳✳]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: ONPress [PF5] key tostore the adjust-ment value.1) Adj item: [DQT FineDeviation (Narrow)]Deviation meterLPF: 3kHzHPF: OFFDetector: ±PEAK/2PTT: Press [Trans-mit] button.Press [OK] buttonto store the adjust-ment value.Write the value asfollowings.99 (Referencevalue)0.35kHz±25Hz*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 69.Balance adjustment is common with the adjustment of all signaling deviation.