TK-7180H/7182H59Test Equipment Required for AlignmentTest Equipment Major Specifications1. Standard Signal Generator Frequency Range 136 to 174MHz(SSG) Modulation Frequency modulation and external modulationOutput 0.1μV to greater than 1mV2. Power Meter Input Impedance 50ΩOperation Frequency 136 to 174MHz or moreMeasurement Capability Vicinity of 50W3. Deviation Meter Frequency Range 136 to 174MHz4. Digital Volt Meter Measuring Range 1 to 20V DC(DVM) Accuracy High input impedance for minimum circuit loading5. Oscilloscope DC through 30MHz6. High Sensitivity Frequency Range 10Hz to 600MHzFrequency Counter Frequency Stability 0.2ppm or less7. Ammeter 13A or more8. AF Volt Meter Frequency Range 50Hz to 10kHz(AF VTVM) Voltage Range 3mV to 3V9. Audio Generator (AG) Frequency Range 50Hz to 5kHzOutput 0 to 1V10. Distortion Meter Capability 3% or less at 1kHzInput Level 50mV to 10Vrms11. Voltmeter Measuring Range 10 to 1.5V DC or lessInput Impedance 50kΩ/V or greater12. 4Ω Dummy Load Approx. 4Ω, 20W13. Regulated Power Supply 13.6V, approx. 20A (adjustable from 9 to 20V)Useful if ammeter equipped18 1 : BLC2 : +B3 : GND4 : PTT/TXD(PC serial datafrom radio)MIC connector (Front panel view)5 : MICE6 : MIC7 : HOOK/RXD(PC serial datato radio)8 : DMTest cable for microphone input (E30-3360-08)3245678312456781 GREENREDBLACKBLUESHIELDWHITEGRAYYELLOWPTTEMIC-EMICHKTuning cable (E30-3383-05)Adapter cable (E30-3383-05) is required for inject-ing an audio if PC tuning is used.See “PC Mode” section fot the connection.Lead wire +MICShield wire –ADJUSTMENT (TK-7182H)