Language Dictionary 3Keysight Models 6811C, 6812C, and 6813C Programming Guide 125FREQuency:SLEW:MODEThis command determines how the frequency slew rate is controlled during atriggered output transient. The choices are as follows:– FIXed: The frequency slew rate is unaffected by a triggered output transient.– STEP: The frequency slew rate is programmed to the value set byFREQuency:SLEW:TRIGgered when a triggered transient occurs.– PULSe: The frequency slew rate is changed to the value set byFREQuency:SLEW:TRIGgered for a duration determined by the pulsecommands.– LIST: The frequency slew rate is controlled by the frequency slew list when atriggered transient occurs.FREQuency:SLEW:TRIGgeredThis command sets the rate at which frequency changes during a triggered outputtransient. Instantaneous frequency changes can be obtained by sendingMAXimum or INFinity. The SCPI keyword INFinity is represented by the number9.9E37.Command syntax [SOURce:]FREQuency:SLEW:MODE Parameters FIXed | STEP | PULSe | LIST*RST value FIXedExamples FREQ:SLEW:IMM 75 FREQ:SLEW MAXQuery syntax [SOURce:]FREQuency:SLEW:MODE?Returned parameters Related commands FREQ FREQ:SLEW:TRIGCommand syntax [SOURce:]FREQuency:SLEW:TRIGgered | INFinityParameters 0 to 9.9E37 | MAXimum | MINimum | INFinity*RST value MAXimumExamples FREQ:SLEW:TRIG 75 FREQ:SLEW:TRIG MAXQuery syntax [SOURce:]FREQuency:SLEW:TRIGgered?Returned parameters Related commands FREQ FREQ:SLEW:MODE