Contents - safety notices
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What You Will Find in This Chapter
- Keysight EXA Signal Analyzer Overview
- Instrument Option Descriptions
- Signal Analyzer Accessories
- Ohm Load
- RF and Transient Limiters
- Before You Start Troubleshooting
- ESD Information
- Handling of Electronic Components and ESD
- Service Equipment You Will Need
- Front End Controller Troubleshooting Kit
- USB Keyboard and Mouse
- Required Test Equipment List
- After an Instrument Repair
- Contacting Keysight Technologies
- Instrument Serial Numbers
- How to Return Your Instrument for Service
- Other Packaging
- Check the Basics
- Instrument Boot Up Process
- Typical instrument boot-up process flow
- Potential Problems During Boot Process
- Green Power On LED Does Not Illuminate
- Fan(s) Are Not Operating
- No Agilent/Keysight Splash Screen Displayed
- Instrument Hangs at the Agilent/Keysight Splash Screen
- Operating System
- Verify LCD Backlight Functionality
- Verify Video Signal Path Integrity
- Fails an Initial Alignment
- Signal Level Verification
- Input Frequencies > 3.6 GHz
- Introduction
- Event and Condition Categories
- Event Message Format
- Event Queues
- Advisory Messages
- Operation Complete Event
- Request Control Event
- User Request Event
- Power on Event
- to -499, Query Errors
- to -399, Device-Specific Errors
- Settings Conflict Errors
- to -299, Execution Errors
- to -199, Command Errors
- Error
- Condition Errors 1 to 99, Calibration
- Condition Errors 36 to 64, Calibration Needed or Failed
- Condition Errors 65 to 92, Calibration Needed (Extended)
- Condition Errors 67 to 95, Calibration Failure (Extended)
- Condition Errors 101 to 199, Measurement Integrity
- Condition Errors 201 to 299, Signal Integrity
- Condition Errors 301 to 399, Uncalibrated Integrity
- Condition Errors 401 to 499, Power
- Condition Errors 501 to 599, Frequency
- Condition Errors 601 to 699, Error Summaries
- Condition Errors 701 to 799, Operation
- Condition Errors 801 to 899, Temperature
- RF Section Description
- RF Section Theory of Operation
- Troubleshooting
- Troubleshooting a Low Band Problem
- Quick Check to Verify High Band RF Path #1
- Troubleshooting a High Band Problem
- High Band Preamp (P07, P13, P26)
- Microwave Preselector Bypass (Option MPB)
- A9 Input Attenuator A
- A13 RF Front End Assembly (Options 532, 544)
- Quick Check to Verify High Band RF Path
- A15 Front End Control Description
- A15 Front End Control Assembly Troubleshooting
- Verifying Input Attenuator A, Input Attenuator B, Low Band Switch Logic and Power Supplies
- Preselector Tune Output
- Verifying Microwave Preselector Bypass Switch (Option MPB)
- Verifying Aux IF Out, Rear Panel (Option CR3, CRP only)
- Verifying Option CR3
- Verifying Option CRP
- MHz BW IF Section
- A2 Analog I.F. Assembly Theory of Operation
- A2 Analog I.F. Troubleshooting
- A3 Digital I.F. Assembly Description
- A3 Digital I.F. Assembly Theory of Operation
- A3 Digital I.F. Troubleshooting
- A2 Analog IF Assembly Theory of Operation
- A2 Analog IF Troubleshooting
- A3 Digital IF Assembly Description
- A3 Digital IF Assembly Theory of Operation
- A3 Digital IF Troubleshooting
- A14 L.O. Synthesizer Assembly Description
- A14 L.O. Synthesizer Theory of Operation
- A14 L.O. Synthesizer Troubleshooting
- Verifying the 4800 MHz Input Power & Frequency Stability
- Verifying the 1st L.O. Output Power
- A16 Reference Assembly Description
- A16 Reference Assembly Troubleshooting
- Diagnostic LEDs
- A4 CPU Description
- Disk Drive
- Power Supply Control
- Rear Panel Connectivity
- System Processor
- A5 Disk Drive
- Overview
- Troubleshooting software related issues
- Reloading the X-Series Software
- Disk Drive Recovery Process
- Using the Instrument Recovery System
- A6 Power Supply Description
- Power Supply Theory of Operation
- A7 Midplane Description
- A7 Midplane Assembly Troubleshooting
- A8 Motherboard Description
- A8 Motherboard Troubleshooting
- A1 Front Panel Assembly
- Block Diagrams
- Reference and Synthesizer Block Diagram
- EXA Computer Block Diagram
- Secure Service Access, Software Versions A.01.xx through A.03.xx
- Menus
- Service Key Descriptions
- Corrections
- Band Lock
- LO Band Lock
- Align
- How to Order Parts
- Replaceable Parts
- Hardware
- Before Starting
- Tools you will need
- Major Assembly Locations
- Instrument Outer Case
- Option PRC
- Top Brace and Reference Bracket
- Replacement
- RF Area (Option 503, 507, 513, 526)
- Low Band Switch Standard Instruments with Serial Number > MY/SG50510001
- Options DP2, MPB, B40
- Attenuators
- YTF Preselector
- RF Area (Option 532, 544)
- Low Band Switch
- RF Front End Assembly - Options 503, 507, 513, 526
- RF Front End Assembly - Options 532, 544
- Front End Control Assembly
- L.O. Synthesizer Assembly
- Rear Panel
- Reference Assembly
- Power Supply Assembly
- CPU Assembly
- Internally Mounted Disk Drive
- Disk Drive Interconnect
- Analog I.F. (AIF)/Digital I.F. (DIF) Assembly
- Separate AIF/DIF Assembly
- Midplane Assembly
- Motherboard Assembly
- Fan Assembly
- Input Connector Assembly
- Front Frame Assembly
- Bail Handle Removal (Option PRC)
- Front Frame Assembly Components - LCD
- Front Frame Assembly Components - LED
- Post-Repair Procedures
- Additional Tasks
- Functional Test Versus Performance Verification
- Before Performing a Functional Test
- Test Equipment
- Displayed Average Noise Level (DANL)
- Frequency Readout Accuracy
- Procedure
- Second Harmonic Distortion (SHD)
- Amplitude Accuracy at 50 MHz
- Testing Preamp Option (P03, P07, P13, P26, P32, P44)
- Frequency Response (Flatness)
- Frequency Response (Flatness), Preamp On
- Scale Fidelity
- Instrument Software Overview
- Software Licensing
- Software Updates
|
Keysight N9010A EXA Service Guide 19OverviewSignal Analyzer Accessories50 Ohm LoadThe Keysight 909 series loads come in several models and options providing avariety of frequency ranges and VSWRs. Also, they are available in either 50ohm or 75 Ohm. Some examples include the:909A: DC to 18 GHz909C: DC to 2 GHz909D: DC to 26.5 GHz50 Ohm/75 Ohm Minimum Loss PadThe Keysight 11852B is a low VSWR minimum loss pad that allows you tomake measurements on 75 Ohm devices using an analyzer with a 50 Ohminput. It is effective over a frequency range of DC to 2 GHz.75 Ohm Matching TransformerThe Keysight 11694A allows you to make measurements in 75 Ohm systemsusing an analyzer with a 50 Ohm input. It is effective over a frequency range of3 to 500 MHz.AC ProbeThe Keysight 85024A high frequency probe performs in-circuit measurementswithout adversely loading the circuit under test. The probe has an inputcapacitance of 0.7 pF shunted by 1 MΩ of resistance and operates over afrequency range of 300 kHz to 3 GHz. High probe sensitivity and low distortionlevels allow measurements to be made while taking advantage of the fulldynamic range of the spectrum analyzer.AC Probe (Low Frequency)The Keysight 41800A low frequency probe has a low input capacitance and afrequency range of 5 Hz to 500 MHz.Broadband Preamplifiers and Power AmplifiersPreamplifiers and power amplifiers can be used with your spectrum analyzer toenhance measurements of very low-level signals.— The Keysight 8447D preamplifier provides a minimum of 25 dB gain from100 kHz to 1.3 GHz.— The Keysight 87405A preamplifier provides a minimum of 22 dB gain from10 MHz to 3 GHz. (Power is supplied by the probe power output of theanalyzer.)— The Keysight 83006A preamplifier provides a minimum of 26 dB gain from10 MHz to 26.5 GHz.
PreviousNext |