12EN5.3 - Advanced programming of the automation’s movementWith this procedure, the control unit memorises the times and power required for opening and closing the system.Moreover, this procedure allows for setting:- start point of gate deceleration area or its deletion- reverse direction of travelPrior to proceeding with the programming procedure, verify that dip-switches 1 and 2 have been correctly set.Once programming is complete, the reverse motor direction settings will remain in force until the control unit is reset orprofessionally reprogrammed.DIP DIP-SWITCH status Description of operationDIP 1-2MOTORON ON Connected gearmotors: swinging series “Jet 24V”, “Linear 24V”, “Intro 24-400” or “Couper24”ON OFF Connected gearmotors: “Modus” series swing gateOFF ON Connected gearmotor: sliding series “Dynamos 24V”OFF OFF Connected gearmotor: swinging series “Minimodus”1. PUT THE GATE LEAF/LEAVESIN THE INTERMEDIATEPOSITION2. PRESS THE SET BUTTONFOR 2 SECONDS3. PRESS THE RADIO BUTTONFOR 1 SECONDThe yellow “set” LED flashes(if not, consult Paragraph 16.1)The yellow “set” LED turns onin the fixed mode7. PRESS THESET BUTTON ORA PROGRAMMED TRANSMITTERBUTTON6. THE CONTROL UNIT PERFORMS AFULL CLOSING MOVEMENT4. THE CONTROL UNIT PARTLY OPENSTHE GATEThe yellow “set” LED flashes5. THE CONTROL UNIT WAITS FOR THEMOTORS TO CHANGE THE DIRECTIONOF THEIR OPENING MOVEMENT FOR8 SECONDS (SEE TABLE A)OR PRESS SETTO PROCEEDThe yellow “set” LED stays on The yellow “set” LED stays on The yellow “set” LED flashes8. THE CONTROL UNIT PER-FORMS THE OPENINGMOVEMENT9. FOR SLOWING DOWN THE OPENING PHASE, DURING THE MOVEMENT PRESS THESET BUTTON OR A PROGRAMMED TRANSMITTER BUTTON TO SET THE SLOWDOWNSTART POINT. ALTERNATIVELY, WAIT UNTIL THE MOVEMENT HAS BEEN COMPLETEDThe yellow “set” LED stays on The yellow “set” LED stays on12. THE CONTROL UNIT PER-FORMSA FULL CLOSING MOVEMENT11. PRESS THE SETBUTTON OR A PROGRAMMEDTRANSMITTER BUTTON10. THE CONTROL UNIT COMPLETESTHE OPENING PHASEThe yellow “set” LED stays on The yellow “set” LED stays on The yellow “set” LED stays onLEAF 1(gate leaf that opens first, bydefault the motor is connectedto the “MOTOR 1”)LEAF 2(gate leaf that opens second, bydefault the motor is connectedto the “MOTOR 2”)7