7ENIf the “PHO2” dip-switch is put to OFF, the safety devices for theopening phase (see Paragraph 8.6) are set as edges: they interveneonly during the opening phase by inverting the movement (thus clos-ing the gate fully). The safety devices for the closing phase do notintervene.DIP6 “HAZ”:If the dip-switch is put to ON, the warning light is powered (terminals1, 2) in the intermittent mode. If the “HAZ” dip switch is set to OFF,power to the flasher is constant (terminals 1 and 2).DIP7 “FAST”:If the “FAST” dip-switch is put to ON, the rapid re-closing functionis activated. This mode closes the gate as soon as the control unitsees that the photocells (if any) connected to the “PHO1” input areobscured and cleared (regardless of any other settings). Therefore,leaving (or entering from) the gate causes the automation to immedi-ately re-close without waiting for the pause time.If the “FAST” dip-switch is put to OFF, the rapid re-closing functiondeactivates.DIP8 “FUNC”:SWING GATE (DIP1/2= ON ON / ON OFF/ OFF OFF)If the “FUNC” dip switch is set to ON this activates the ram function,which is advisable if an electric lock is installed (see par. 8.5). This de-livers a transient voltage peak at the start of the opening stroke andthe end of the closing stroke to overcome the resistance of the pawl.If the “FUNC” dip switch is set to OFF the ram function is disabled.SLIDING GATE (DIP1/2= OFF/ON)Changing the position of the “FUNC” dip switch changes the open-ing stroke direction. This is read only at the beginning of basic oradvanced programming.3.2 - Trimmer adjustment1 2 3 4 5 6 7 8Trimmer DescriptionPOWER Power: adjustment of motor power. Turning the trimmer clockwise increases the motor’s power.To validate the modification it is necessary to programme the gate path..OBS Obstacle, sensitivity to obstacles: adjustment of the obstacle detection function. Turning the trimmer clockwiseincreases the drive time before obstacle detection (less sensitivity). Therefore, in systems with particularly unfa-vourable mechanical conditions, it is advisable to keep the drive time high.PAUSE Pause time before automatic gate closing. Turning the trimmer clockwise increases the pause time from 0 to180 seconds. Please note: the AUTO dip-switch must be put to ON.DELAY Staggered closing of the gate leaves: In case of two connected motors, it adjusts the staggering of the leaves.Turning the trimmer clockwise increases the stagger time from 0 seconds until complete staggering.Varying the “POWER” trimmer has no effect until the stroke is reprogrammed (par. 5).In normal operation, if the “delay” trimmer is set to too low a value (not “zero”: the gate sections must be offset to preventthem overlapping) and section 1 arrives before section 2, the control unit will automatically open the gate slightly and the closethe sections in the correct order (anti-overlapping mechanism).3PAUSADELAYTRIMMERMAXOBSTACLEPOWER