112999 - 1 www.Laundrylux.com 37There are three L.E.D. indicators (“red” lights) located at thelower back side area of the microprocessor controller(computer) which are identified/labeled as “DOOR,” “HEAT,”and “MTR” (motor). These L.E.D.s indicate that the output sof the microprocessor controller (computer), or in the case ofthe door switch, the inputs are functioning.“DOOR” – L.E.D. SHOULD BE ONALL THE TIME (even if thedryer is not running) unless the main door is open or there isa problem (open circuit) in the main door switch circuit.NOTE: If the dryer is started (the display L.E.D. indicatordots are on) and there are no outputs (“HEAT” and/or“MTR” output L.E.D. are off) and the “DOOR” input L.E.D.is on, the fault is in the Phase 5 microprocessor controller(computer) itself.If the failure was elsewhere (i.e. dryer’s door switch circuit)the L.E.D. display would read “door” if a keypad entry wasattempted. If the display L.E.D. indicators are on, and thedoor L.E.D. indicators are on, and the door L.E.D. inputand motor/heat output L.E.D.s are on, yet the motor and/orheat is not active (on); then the problem is not the doorswitch on the Phase 5 microprocessor controller(computer), the problem is elsewhere in the dryer.“HEAT” – Output L.E.D. Indicator – if the dryer is started andthere is no heat, yet the microprocessor controller (computer)L.E.D. display heat indicator dot is on, but the heat outputL.E.D. indicator is of f, then the fault is in the Phase 5microprocessor controller (computer) itself. If both the displayheat output L.E.D. indicator are on, then the problem iselsewhere (external of the microprocessor controller[computer]).“MTR” (motor) – Output L.E.D. Indicator – if the dryer is startedand the motor is not operating, yet both the microprocessorcontroller (computer) L.E.D. display motor indicator dot and“DOOR” input L.E.D. indicator are on, but the “MTR” outputL.E.D. indicator is of f; then the fault is in the Phase 5microprocessor controller (computer) itself. If the motor is notoperating and the “MTR” output indicator is on, then theproblem is elsewhere (external of the microprocessor controller[computer]).Phase 5 Auto Cycle(Patent No. 4,827,627) ________________“A” and “b” Factor ParametersThe L.E.D. indicator dot s located at the top portion of thedisplay indicates the various microprocessor controller(computer) output functions while a cycle is in progress.Thesedots do not necessarily mean that the outputs are functioning.They are only indicating that the function (output) should beactive (on).Heat Circuit Indicator – indicator dot is on whenever themicroprocessor controller (computer) is calling for the heatingcircuit to be active (on).Motor Circuit Indicator – indicator dot is on whenever a cycleis in progress.Phase 5 Microprocessor Controller(Computer) Relay Output L.E.D. IndicatorsGAS ELECTRICModel “A” “b” Model “A” “b”DAWF0GM/NM 5 75 DAWF0EM/NMN / ADAWS0GM/NM 5 75 DAWS0EM/NMDAWS2GM/NM 5 75 DAWS2EM/NM* “A” and “b” Factors N/A at time of printing.Contact factory for models and/or “A” and “b” factors not listed.IMPORTANT: The “A” and “b” Factors have beenpreprogrammed by the factory and should be changed inthe field unless the Phase 5 coin microprocessor controller(computer) should fail and is replaced. THEREPLACEMENT PHASE 5 COIN MICROPROCESSORCONTROLLER (COMPUTER) MUST BEREPROGRAMMED FOR THE SPECIFIC MODEL SHOWNIN THE CHART ABOVE.Optional 9 Volt Battery Backup ______Dryers ordered from the factory with the 9 volt battery backupoption (battery is not included) allow the Phase 5microprocessor controller (computer) to maintain its operatingstatus should a momentary power interruption occur while thedryer cycle is in progress.It is suggested that the battery be replaced at least once ayear or as found necessary . The battery life will depend onthe age of the battery, the amount of power interruptions, andthe backup time used.IMPORTANT: For proper operation use alkaline batteriesonly. Suggest Energizer, Duracell or equivalent. DO NOTUSE CARBON TYPE BATTERIES.