8 Laundrylux 112999 - 1Formula: (LCdE/AtSt) (tFAS) = Vended Time for “ LCdE”(25¢/50¢) (30) = 15 minutesSettings: PL09 (LCdE) ...................... 25PL11 (tFAS) ........................ 30PL12 (AtSt) ........................ 50(Dual Coin)In the Accumulative Time (AtIn) Mode, when using a dual coinacceptor, once the “AmountTo Start” (“AtSt”) has been inserted,the addition of a coin(s) yields more time.The vended time for additional coins is determined by thePhase 5 coin microprocessor controller (computer) calculation.There is no calculation required by the owner.Formula: (LCdE/AtSt) (tFAS) = Vended TimeExample No. 1: Using a 10¢/25¢ dual coin acceptor with thedesired “Amount to S tart” (“AtSt”) being 25¢ for 15 minutes,each additional 10¢ would yield the following:Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE”(10¢/25¢) (15 minutes) 6 minutesSettings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 15PL12 (AtSt) ........................ 25Example No. 2: If the dryer is equipped with a 10¢/25¢ dualcoin acceptor and the desired “Amount To Start” (“AtSt”) is35¢ for 14 minutes, each additional 10¢ inserted would yield4 minutes and each additional 25¢ would yield 10 minutes.Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE”(10¢/35¢) (14 minutes) 4 minutesSettings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 14PL12 (AtSt) ........................ 35Example No. 3: If the dryer is equipped with a 10¢/25¢ dualcoin acceptor and the desired “Amount To Start” (“AtSt”) is55¢ for 33 minutes, each additional 10¢ inserted would yield6 minutes, and each additional 25¢ would yield 15 minutes.Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE”(10¢/55¢) (33 minutes) 6 minutesSettings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 33PL12 (AtSt) ........................ 55NOTE: If the total Vend Time cannot be divided evenly bythe “Amount To Start” (“AtSt”), the “Time For Amount ToStart” will calculate precisely the amount of the timeentitled to the purchaser.Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE”(10¢/35¢) = 2.85 minutes(2 minutes and 51-seconds)Settings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 10PL12 (AtSt) ........................ 35Accumulative Coin (ACOn)When this program mode (“ACOn”) is selected, additional timecan only be achieved when the “Amount For Additional Time”(“AFAt”) PL13 has been inserted.NOTE: When programming, to use the Accumulative CoinMode (“ACOn”), the following parameters/programs needto be checked and/or changed accordingly:Settings: PL01 ......................... “ACOn”(“Accumulative Coin”)PL13 ........................... “AFAt”(“Amount For Additional Time”)(Single Coin Acceptor)Example No. 1: Using a 25¢ coin acceptor with the desired“Amount To Start” (“AtSt”) being 50¢ for 24 minutes, the Phase5 coin microprocessor controller (computer) would yield moretime (24 minutes) only when an additional 50¢ is inserted.For this application, the “T ime For Amount To Start” (“tFAS”)program (PL11) is determined as follows:Formula: (AFAt/AtSt) (tFAS) = Vended Time for “AFAt”(50¢/50¢) (24 minutes) = 24 minutesSettings: PL09 (LCdE) ...................... 25PL11 (tFAS) ........................ 24PL12 (AtSt) ........................ 50PL13 (AFAt) ....................... 50(Dual Coin Acceptor)With a dual coin acceptor the “T ime For Amount To S tart”(“tFAS”) is determined as shown below:Formula: (AFAt/AtSt) (tFAS) = Vended Time for “AFAt”Example No. 1: Using a 10¢/25¢ dual coin acceptor the desired“Amount To Start” (“AtS t”) is 50¢ for 20 minutes and the“Amount for Additional Time” (“AFAt”) is set for 20¢ eachadditional 20¢ would yield 8 minutes.Formula: (AFAt/AtSt) (tFAS) = Additional Vended Time(20/50) (20 minutes) = 8 minutesSettings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 20PL12 (AtSt) ........................ 50PL13 (AFAt) ....................... 20Example No. 2: If the dryer is equipped with a 10¢/25¢ dualcoin acceptor and the desired “Amount To Start” (“AtSt”) is35¢ for 14 minutes and the “Amount For Additional Time”(“AFAt”) is set for 25¢, each additional 25¢ inserted wouldyield 10 minutes.Formula: (AFAt/AtSt)(tFAS) = Vended Time for “AFAt”(25¢/35¢) (14 minutes) = 10 minutesSettings: PL09 (LCdE) ...................... 10PL10 (rCdE) ....................... 25PL11 (tFAS) ........................ 14PL12 (AtSt) ........................ 35PL13 (AFAt) ....................... 25