166. TECHNICAL DATABasic parameters:- analog output galvanicaly isolated:- current 0/4...20 mA- voltage 0...10 V- maximal load resistance of thecurrent output £ 500 W- minimal load resistance of thevoltage output ³ 500 W- accuracy class 1) 0.2- averaging time of the transducer:- range: d.c. current [mA], d.c. voltage [V] ³ 0.1 s- other ranges ³ 0.3 s- consumption < 2 VA- preheating time of the transducer 10 min- transducer response time:- range: d.c. current [mA], d.c. voltage [V] ³ 0.2 s- other ranges ³ 0.4 s- current flowing through RTD < 0.2 mA- resistance of wires connectingRTD with the transducer £ 10 WRated operating conditions:- supply depending on theexecution code 85... 253 V a.c./d.c.20...85 V d.c., 20...65 V a.c.- frequency of the supply a.c. voltage 45... 65 Hz- ambient temperature – 20...23...55°C- storage temperature – 25...85°C- related air humidity < 95% (condensationinadmissible)- working position any