42Regi-ster Value Meaning4020 24 24 – 3-phase power (P)4021 -800-100 – -100.0% (percentage value with one place afterthe decimal point multiplied by 10) the lower value of therated 3-phase power,(3 x 4 A x 230 V x cos (180°)/3 x 5 A x 230 V) x 1000 = - 8004022 8001000 – 100.0% (percentage value with one place afterthe decimal point multiplied by 10) the upper value of therated 3-phase power,(3 x 4 A x 230 V x cos (0°)/3 x 5 A x 230 V) x 1000 = 8004023 -2000-2000 – -20.00 mA (value in mA with two places afterthedecimal point multiplied by 100) lower value of theoutput current.(20.00 mA x 100) = - 20004024 20002000 – 20.00 mA (value in mA with two places afterthe decimal point multiplied by 100) upper value of theoutput current.(20.00 mA x 100) = 20004025 0 0 – normal mode of the continuous output 1Table 9For the rated execution 3 x 5 /230 V, one must set values from the table 9