Installation Instructions Section 222 Part Number 000007345 2/14Installation Check List Is the Ice Machine level? Have all of the electrical and waterconnections been made? Has the supply voltage been tested andchecked against the rating on the nameplate? Is there proper clearance around the icemachine for air circulation? Is the ice machine grounded and polaritycorrect? Has the ice machine been installed whereambient temperatures will remain in therange of 35° - 110°F (1.6° - 43.3°C)? Has the ice machine been installed where theincoming water temperature will remain in therange of 35° - 90°F (1.6° - 32.2°C)? Is there a separate drain for the potablewater, bin and water-cooled condenser? Are the ice machine and bin drains vented? Are all refrigerant lines free from contact withother components? Are all electrical leads free from contact withrefrigeration lines and moving equipment? Has the owner/operator been instructedregarding maintenance and the use ofManitowoc Cleaner and Sanitizer? Has the owner/operator completed thewarranty registration card? Has the ice machine and bin been sanitized? Is the ice thickness control set correctly?(Refer to Operational Checks to check/set thecorrect ice bridge thickness).Additional Checks for Remote Models Has the receiver service valve been opened? Does the remote condenser fan operateproperly after start-up? Has the remote condenser been locatedwhere ambient temperatures will remain inthe range of -20° - 120°F (-29 - 49°C). Is the line set routed properly? Are both refrigeration lines to remotecondenser run so they do not lay in water andare properly insulated?Before Starting the Ice MachineAll Manitowoc ice machines are factory-operated andadjusted before shipment. Normally, new installations donot require any adjustment.To ensure proper operation, follow the OperationalChecks in Section 3 of this manual. Starting the icemachine and completing the Operational Checks are theresponsibilities of the owner/operator.Adjustments and maintenance procedures outlined inthis manual are not covered by the warranty.Follow the procedures on the next page and in section 3to verify the control board settings are correct for yourcustomers location and application.! WarningPotential Personal Injury SituationDo not operate equipment that has been misused.abused, neglected, damaged, or altered/modifiedfrom that of original manufactured specifications.