Maintenance 15-189MSR Cleaning ProceduresMSR Cleaning Cards and MSR Treatment Cards may be purchased from NCR or KICProducts. For details, see http://www.ncr-direct.com or http://www.kicproducts.com.MSR Cleaning and Treatment CardsPart Part Number NCR Part NumberMSR Cleaning Card, Dry 998-0052929MSR Cleaning Card, Wet 520522 (box of 50) 603-9014730MSR Treatment Card 9436-2446 (box of 20) 497-0453056MSR Treatment CardThe MSR Treatment Card is used to assist in protecting Magnetic Stripe Readers fromElectrostatic Discharge (ESD), which can cause failures when swiping cards that havemetallic hologram stripes.Swipe the card through the MSR in a smooth motion. Only swipe it down ONCE andup ONCE. Allow the device to dry for 5 minutes before swiping any other cards.Note: Each long side of the card may be used twice. Each short side of the card may beused only once. Thus, a single card can treat 6 MSR devices with one UP and oneDOWN swipe per MSR device. These limits should not be exceeded due to thepossibility of spreading contaminants from machine to machine and/or reducing ESDprotection.Note: If all six up/down swipes are not used on a fresh card it should be placed in asealed (Ziploc) bag for future use.