Upgrading Your System 4-25Installing or Swapping a Hard Disk Drive in a Hot-Swap BayThis procedure describes installing a new hard disk drive or swapping out afaulty drive from one of the six hot-swap SCSI disk drive bays. The SCSI drivesmust use the industry standard 80-pin Single Connector Attachment (SCA)connector. Each drive must be installed in a drive carrier.Note: To order a disk with a carrier, contact your salesrepresentative or dealer.! If installing new drives, follow an installation scheme starting with theleft-most drive. Fill the bays left-to-right (1 through 6). See Figure 4-23.0 1 2 3 4 51 2 3 4 5 6ABFigure 4-23. SCSI Disk Drive Installation Scheme! The hard disk SCSI address assignment is:Bay Device SCSI ID Address1 First Hard Disk (Left) 02 Second Hard Disk 13 Third Hard Disk 24 Fourth Hard Disk 35 Fifth Hard Disk 46 Sixth Hard Disk (Right) 5! If an individual SCSI drive fault LED (yellow light) is on steadily, thisindicates that the drive has been flagged as faulty by the RAID hostcontroller (See Figure 4-23,A). Follow the procedure described in thissection to remove the faulty drive and swap in a good one.