1. POST Error MessageExpress5800/R120f-2E, T120f Maintenance Guide192Chapter 3 AppendixError Message Cause SolutionB800 DXE_PCI_BUS_OUT_OF_RESOURCES Resources to be allocated toPCI expansion card wasinsufficient.Contact your sales representative.C000 The error occurred duringfan sensor reading.An error was detected whilereading fan sensor.C010 The error occurred duringtemperature sensor readingAn error was detected whilereading temperature sensor.C011 System Temperature out ofthe range.A temperature abnormality wasdetected.The cooling fan has failed or is clogged.Contact your sales representative.C020 The error occurred duringvoltage sensor reading.An error was detected whilereading voltage sensor.Contact your sales representative.C021 System Voltage out of therange.A system voltage abnormalitywas detected.C040 SROM data read error An error was detected whilereading data on SROM.C061 1st SMBus device Errordetected.An error was detected on 1stSM Bus.C062 2nd SMBus device Errordetected.An error was detected on 2ndSM Bus.C063 3rd SMBus device Errordetected.An error was detected on 3rdSM Bus.C064 4th SMBus device Errordetected.An error was detected on 4thSM Bus.C065 5th SMBus device Errordetected.An error was detected on 5thSM Bus.C066 6th SMBus device Errordetected.An error was detected on 6thSM Bus.C067 7th SMBus device Errordetected.An error was detected on 7thSM Bus.C068 8th SMBus device Errordetected.An error was detected on 8thSM Bus.Contact your sales representative.C101 BMC Memory TestFailed.An error was detected on BMC. Unplug the power cord, wait for at least 30seconds, then restart the server. If the same erroris detected repeatedly, contact your salesrepresentative.C102 BMC Firmware CodeArea CRC check Failed.C103 BMC core hardware failure.C104 BMC IBF or OBF check failed. An error was detected whileaccessing BMC.C105 BMC SEL area full. There is not enough space tostore the system event log.Run Offline Tools (Chapter 1, 9. Offline Tools)and delete the event logs.C10C BMC update firmwarecorrupted.An illegality was detected whileupdating BMC firmware.Unplug the power cord, wait for at least 30seconds, then restart the server. If the same erroris detected repeatedly, contact your salesrepresentative.C10D Internal Use Area of BMC FRUcorrupted.An illegality was detected inFRU containing the deviceinformation.C10E BMC SDR Repository empty. An error was detected on BMCSDR.C10F IPMB signal lines do notrespond.Failure of Satellite ManagementController was detected.Unplug the power cord, wait for at least 30seconds, then restart the server. If the same erroris detected repeatedly, contact your salesrepresentative.C110 BMC FRU device failure. An error was detected in FRUthat contains deviceinformation.C111 BMC SDR Repository failure. Failure was detected in SROMthat stores the SDR.C112 BMC SEL device failure. Device failure was detected inBMC SEL.C113 BMC RAM test error. An error was detected in BMCRAM.C114 BMC Fatal hardware error. A hardware error was detectedin BMC.