Installing and Using Utilities 5-83z On the other hand, if the BIOS version of the running CPU/IO module is older than the one ofthe module to be installed later, after installing the module and making the system duplexed,the firmware is updated by temporarily stopping the running module and starting it again.While using this function, the module is switched automatically, and the [GeminiEngineMonitor Tool] window is displayed. Wait until the window closes automatically withoutperforming operations such as starting, stopping and diagnosing modules. Set whether toenable this function on the setup window described later. Also, if updating the firmware stopswithout completion, check the system status with ftServer Utility or event log, and start themodule that has been stopped.Setup WindowGeminiEngine Monitor Tool can be set on the following setup window:From the Start menu, select [All Programs], [GeminiEngine Monitor Tool] and then[Configuration].If you start the configuration function, the following [GeminiEngine Monitor Tool Configuration]window is displayed. Below explains the check boxes and actions to be taken when they areselected:Action for detecting failed redundant: You can set actions for when the status changes fromduplex to simplexz Beep: If the server status changes from duplex to simplex, the tool sounds beeps at a fixedinterval.z Warning message: If the server status changes from duplex to simplex, a warning message isdisplayed.