7-4 TroubleshootingPOST Error MessagesPowering on the server automatically starts the self-diagnostic program, POST (Power OnSelf-Test). When POST detects any error, it displays an error message and its measure on thedisplay unit. Follow the table below to troubleshoot such errors.Phoenix BIOS 4.0 Release 6.0.XXXX:CPU=Pentium III XXX MHz0640K System RAM Passed0127M Extended RAM PassedWARNING:02B0: Diskette drive A error.:press to resume, to SETUPMessage indicating a floppy disk drive errorTIPS:For error messages on optional PCI boards, refer to the manual provided with those options.On-screen error message Cause Action0200 Failure Fixed Disk • Hard disk is faulty• CPU/IO module is faulty.• Replace the hard disk.• Replace the CPU/IO module.0210 Stuck Key Keyboard connection error • Disconnect the keyboard andconnect it back again.• Replace the keyboard.0211 Keyboard error Keyboard is faulty. • Disconnect the keyboard andconnect it back again.• Replace the keyboard.• If restarting does not help,replace the CPU/IO module.0212 Keyboard ControllerFailedKeyboard controller is faulty. If restarting the server does nothelp, replace the CPU/IO module.0213 Keyboard locked -Unlock key switchKeyboard is locked. Unlock the key switch.0230 System RAM Failed atoffsetDIMM is faulty. • Replace DIMM.• Replace the CPU/IO module.0231 Shadow RAM Failed atoffsetShadow RAM is faulty. • Replace DIMM.• Replace the CPU/IO module.0232 Extended RAM Failed ataddress lineExtended RAM is faulty. • Replace DIMM.• Replace CPU/IO module.0233 Memory type mixingdetectedMemory of the different typesis installed.Memory of the different types isinstalled. Replace DIMM withappropriate one.0250 System battery is dead-Replace and runSETUPSystem battery is dead. • Replace system battery.• Replace CPU/IO module.