CHAPTER 1 GENERAL INFORMATION– 12 – NWA-008853-001 Rev.3.097ch1001.fmService Conditions for Centralized BillingIf all the PBXs within the network are the 2000 IPS, the PBX can be a center billing office. In this case,there are the following conditions:Conditions for Center Office;- The available combination between SMDR and the output format is as follows. One type of SMDR isavailable among the following SMDR in center office.NOTE: The extended NEAX 2400 IMS format is available by using SC-3168 MRCA program issue 2 orlater.- When the center office supports extended NEAX 2400 IMS format, the billing information receivedfrom each local office can be output with either extended NEAX 2400 IMS format or formerNEAX 2400 IMS format. When the center office does not support extended NEAX 2400 IMS format(Series 3300 or earlier), the billing information from each local office can output with only formerNEAX 2400 IMS format.- Maximum of eight local offices can be accommodated.- Maximum of 3600 calls per hour can be received from local office. If exceeds 3600 calls per hour, thebilling information is stored in the local office.SMDR Former NEAX 2400 IMSformatExtended NEAX 2400 IMSformatSMDR with AP00(PN-AP00-B with AP00program)Available Not AvailableSMDR with AP00(PN-AP00-B/PN-AP00-Dwith MRCA program)Available Available[Series 3400 software or later]NOTEMP built-in SMDR onRS-232CNot Available Not AvailableMP built-in SMDR on IP Available[Series 3400 software or later]Available[Series 3400 software or later]JULY/01/2006SYSTEM OUTLINE