Napoleon BL36NTE-1 Installation And Operation Manual
Also see for BL36NTE-1: Installation manualOwner's manualOwner's manualInstallation manual
Contents
|
W415-1705 / A / 07.13.17EN8general informationThis illustration is for reference only. Refer to the rating plate on the appliance for accurate information.1.3 rating plate informationThe rating plate must remain with the appliance at all times. It must not be removed.note:1.4 mobile home installationThis appliance must be installed in accordance with the manufacturer’s instructions and the ManufacturedHome Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile HomeStandard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gasindicated on the rating plate.This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Builtin appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of the base.Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact yourlocal authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance mustbe fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot andthe fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting theappliance, ensure that the logs are positioned correctly.This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home,where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertiblefor use with other gases, unless a certified kit is used.Conversion KitsThis appliance is field convertible between Natural Gas (NG) and Propane (P).To convert from one gas to another, consult your Authorized dealer/distributor.20.1W385-2180Page 1 of 2FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE ÀCOUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISONMOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DEMAISONS MOBILES EQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DESÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANSLE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFERER À LA NORMERELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONSDANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. POURUTILISATION AVEC BARRIÈRE W565-0282 . SUIVEZ LES INSTRUCTIONS D'INSTALLATION QUI SETROUVENT DANS LE MANUEL D'INSTALLATION.DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOMINSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCEWITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION ANDSAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTUREDHOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR USE WITH BARRIERW565-0282. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.9700539 (WSL) 4001657 (NGZ)4001658 (NAC) 4001659 (WUSA)0-4500FT (0-1370m) ALTITUDE / ÉLÉVATION 0-4500FT (0-1370m)17,500 BTU/h INPUT / ALIMENTATION 16,000 BTU/h14,250 BTU/h REDUCED INPUT / ALIMENTATION RÉDUITE 12,500 BTU/hMANIFOLD PRESSURE: 3.5" (9MB) WATER COLUMN MANIFOLD PRESSURE: 10" (25MB) WATER COLUMNPRESSION AU COLLECTEUR: 3.5" (9 MB) D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" (25MB) D'UNE COLONNE D'EAUMINIMUM SUPPLY PRESSURE: 4.5" (11MB) WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" (27MB) WATER COLUMNPRESSION D'ALIMENTATION MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" (27MB) D'UNE COLONNE D'EAUMAXIMUM SUPPLY PRESSURE: 13.0" (32MB) WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" (32MB) WATER COLUMNPRESSION D'ALIMENTATION MAXIMALE: 13.0" (32MB) D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAUP4: 51.7% P4: 51.7%NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORSCERTIFIED WITH THIS APPLIANCE ONLY.WARNING:DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 16"FLOOR / PLANCHER 0 VENT SIDES / CÔTÉS DE L'ÉVENT 1"SIDES / CÔTÉS 0 VENT TOP / ÉVENT SUPÉRIEUR 3"BACK / ARRIÈRE 0 VENT BOTTOM / ÉVENT INFÉRIEUR 1"MANTEL / MANTEAU 12" ** MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTIONMANUAL FOR GREATER EXTENSIONS. RÉFERER AU MANUEL D'INSTRUCTION POUR DESEXTENSIONS PLUS GRANDES.SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.RÉFERER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURSD'ÉVACUATION MINIMALE ET MAXIMALE.WOLF STEEL LTD.24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADAUN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ AVEC CETAPPAREIL. UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉESSEULEMENT AVEC CET APPAREIL.AVERTISSEMENT: N’AJOUTEZ PAS A CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER ENCONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LEFABRICANT.THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERSINSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING ISNECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON.RÉFERER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL ESTIMPORTANT DE BIEN RÉINSTALLER ET RESCELLER L'ÉVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DUSYSTÈME DE PRISE D'AIR.DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCEPRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE.ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZOPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: AUBSERIAL NUMBER/NO. DE SÉRIE: BL36MATERIAL: .010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTERMIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.BLACK ON WHITE BACKGROUNDMAX OVERALL DECAL SIZE: 4.75" x 8.50"HOLE IS 0.250” Ø / 0.312 “FROM BOTTOM AND LEFT EDGE”SERIAL NUMBERS TO BE ASCENDING FROM BL36 274170TITLE: RATING PLATE C/BL36(N)T(E)-1 / C/BL36(P)T(E)-1REVISION: A : Updated BTU || 06.15.17_T.B.DWG#: W385-2180DATE: 02.24.17_T.B.BL36NT CBL36NT MODEL CBL36PT BL36PTBL36NTE CBL36NTE CBL36PTE BL36PTECERTIFIED TO / CERTIFIÉ AUX: CSA 2.22-2016 • ANSI Z21.50-2016 VENTED DECORATIVE GAS APPLIANCES / APPAREILS À GAZ VENTILÉS DÉCORATIFS.ACERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33b - 2008, ANSI Z21.88b- 2008 VENTED GAS FIREPLACE HEATER / APPAREIL DE CHAUFFAGE ALIMENTÉAU GAZ ET VENTILÉVENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THECURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.FOYER DE CHAUFFAGE AU GAZ AVEC ÉVACUATION. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNEMAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LANORME DE SECURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORMERELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A.NOT FOR USE WITHSOLID FUEL. FOR USEWITH GLASS DOORSCERTIFIED WITH THISUNIT ONLY.WARNING : DO NOT ADD ANY MATERIALTO THE APPLIANCE, WHICH WILL COMEIN CONTACT WITH THE FLAMES, OTHERTHAN THAT SUPPLIED BY THEMANUFACTURER WITH THE APPLIANCE.MINIMUM CLEARANCE TOCOMBUSTIBLE MATERIALS:TOP0”FLOOR0”RECESSED DEPTH ONE SIDED 23"RECESSED DEPTH SEE THRU 13.5”FRAMING (NOT INCLUDINGFACE MATERIAL)SIDES0”VENT2"BACK0”MANTLE15" *TOP, SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING MATERIALS. FOR FINISHING MATERIALSSEE OWNERS MANUALUN COMBUSTIBLE SOLIDE NEDOIT PAS ÊTRÉ UTILISÉ AVECCET APPAREIL. UTILISER AVECLES PORTES VITRÉESHOMOLOGUÉES SEULEMENTAVEC CETTE UNITÉ.AVERTISSEMENT: N'AJOUTEZ PAS ACET APPAREIL AUCUN MATÉRIAU DEVANTENTRER EN CONTACT AVEC LES FLAMMESAUTRE QUE CELUI QUI EST FOURNI AVECCET APPAREIL PAR LE FABRICANT.DÉGAGEMENTS MINIMAUX DESMATÉRIAUX COMBUSTIBLES:DESSUS0”PROFONDEUR D'ENCASTRÉ25"PLANCHER0”ÉVENT2"CÔTES0”MANTEAU15" *ARRIÉRE0”MADE IN CANADA / FABRIQUÉ AU CANADAWOLF STEEL LTD. BARRIE, ONTARIO, CANADAALTITUDE / ÉLÉVATIONINPUT / ALIMENTATIONREDUCED INPUT / ALIMENTATION RÉDUITEORIFICE / INJECTEURMANIFOLD PRESSURE /PRESSION AU COLLECTEURMINIMUM SUPPLY PRESSURE /PRESSION D'ALIMENTATION MINIMALEMAXIMUM SUPPLY PRESSURE /PRESSION D'ALIMENTATION MAXIMALE0-4500FT (0-1370M)30,000 BTU/H23,000 BTU/H#383.5" WATER COLUMN/D'UNE COLONNE D'EAU4.5" WATER COLUMN/D'UNE COLONNE D'EAU7.0" WATER COLUMN/D'UNE COLONNE D'EAU0-4500FT (0-1370M)30,000 BTU/H23,000 BTU/H#5310" WATER COLUMN/D'UNE COLONNE D'EAU11" WATER COLUMN/D'UNE COLONNE D'EAU13" WATER COLUMN/ D'UNE COLONNE D'EAUTHE APPLIANCE MUST BE VENTED USING THE APPROPRIATENAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUALFOR VENTING SPECIFICS. PROPER REINSTALLATION ANDRESEALING IS NECESSARY AFTER SERVICING THE VENT-AIRINTAKE SYSTEM.L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLED'ÉVACUATION PROPRE A NAPOLEON. RÉFÉRER AU MANUELD'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATIONPRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER ETRESCELLER L'ÉVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DUSYSTÉME DE PRISE D'AIR.CLASSIFICATION: 115V 0.82AMP, 60HZW385-2007MODEL NATURAL GAS /GAZ NATURALLHD50NTMODEL PROPANELHD50PTSERIAL NUMBER/NO. DE SÉRIE: LV50ELECTRICAL RATING: 115V 0.82AMP, 60HZREFERENCE #W/N 16131* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSIONHORIZONTALE MAXIMALE: 2". SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.DESSUS, COTÉS & ARRIÈRE: SELON LES ESPACEURS DE DÉGAGEMENT POUR LES MATÉRIAUX D'OSSATURESELON LE MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE FINITION.* L'EXTENSION HORIZONTALE MAXIMALE: 2". RÉFÉRER AU MANUEL D'INSTRUCTION POUR DES EXTENSIONSPLUS GRANDES. RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE.TITLE: RATING PLATE C/BL36(N)T(E)-1 / C/BL36(P)T(E)-1 DWG#: W385-2180DATE: 02.24.17_T.B.PAGE 2 OF 2WOLF STEEL LTD.GARDEZ LE BRÛLEUR ET LECOMPARTIMENT DESCONTRÔLES PROPRES.CONSULTEZ LE MANUELD’INFORMATION ETD’INSTALLATION. PARMESURE DE SÉCURITÉ,CET APPAREIL DOITÊTRE ALIMENTÉ EN AIRFRAIS ET AVEC SUFFISANTD’AIR COMBURANT ETDE VENTILATION.WARNING:IMPROPER INSTALLATION,ADJUSTMENT, ALTERATION,SERVICE OR MAINTENANCECAN CAUSE PROPERTYDAMAGE, PERSONALINJURY OR LOSS OFLIFE. REFER TOOWNER’S MANUAL.INSTALLATION ANDSERVICE MUST BEPERFORMED BY AQUALIFIED INSTALLER,SERVICE AGENCY ORTHE GAS SUPPLIER.ATTENTION:UN INSTALLATION OUUNE MODIFICATIONINAPPROPRIÉEDU RÉGLAGE, DU SERVICEET DE L’ENTRETIENPOURRAIENT ÊTRE LA CAUSEDE DOMMAGES À LA PROPRIÉTÉDE BLESSURES CORPORELLESOU MÊME LA MORT. CONSULTERLE MANUEL D’INFORMATION,L’INSTALLATION ET LE SERVICEDOIVENT ÉTRE EXÉCUTÉS PARUN INSTALLATEUR QUALIFIÉPOUR LE GAZ, UNE ENTERPRISEDE SERVICE OU LEFOURNISSEURDE GAZ SEULEMENT.KEEP BURNER ANDCONTROL COMPARTMENTCLEAN. SEE INSTALLATIONAND OPERATINGINSTRUCTIONSMANUAL. APPLIANCENEEDS FRESH AIR FORSAFE OPERATION AND MUSTBE INSTALLED WITHADEQUATE PROVISIONSFOR COMBUSTIONAND VENTILATION AIR. “This appliance is only for use with thetype(s) of gas indicated on the rating plateand may be installed in an aftermarket,permanently located, manufactured home(USA only) or mobile home, where notprohibited by local codes. See installationmanual for details. This appliance is notconvertible for use with other gases,unless a certified kit is used.”«Cet appareil doit être utilisé uniquementavec les types de gaz indiqués sur laplaque signalétique et peut être installédans une maison préfabriquée (É.-U.seulement) ou mobile installée à demeuresi les règlements locaux le permettent.Voir le manuel d’installation pour plus derenseignements. Cet appareil ne peut êtreconverti à d’autres gaz, sauf si unetrousse de conversion est utilisée. »FOR YOUR SAFETY: DONOT STORE OR USE GASOLINEOR OTHER FLAMMABLE VAPORSAND LIQUIDS IN VICINITY OFTHIS OR ANY OTHERAPPLIANCE.CAUTION: DO NOT OPERATETHE FIREPLACE WITH THEGLASS REMOVED, CRACKED ORBROKEN. REPLACEMENT OFTHE GLASS SHOULD BE DONEBY A LICENSED OR QUALIFIEDPERSON.POUR VOTRE SÉCURITÉ:NE PAS ENTREPOSER NIUTILISER D’ESSENCE NID’AUTRES VAPEURS OULIQUIDES INFLAMMABLES DANSLE VOISINAGE DE CET APPAREILOU DE TOUT AUTRE APPAREIL.AVERTISSEMENT: NE PASUTILISER L’APPAREIL SI LEPANNEAU FRONTAL EN VERREN’EST PAS EN PLACE, ESTCRAQUÉ OU BRISÉ. CONFIEZ LEREMPLACEMENT DU PANNEAUÀ UN TECHNICIEN AGRÉÉ.REVISION: A : Updated BTU || 06.15.17_T.B.CAUTION:HOT WHILE OPERATING. DO NOT TOUCH.SEVERE BURNS MAY RESULT. KEEP CHILDRENCLOTHING, FURNITURE, GASOLINE OROTHER FLAMMABLE VAPORS AWAY.AVERTISSEMENT:L’APPAREIL EST CHAUD PENDANT SONFONCTIONNEMENT. BRÛLURES GRAVESPEUVENT EN RÉSULTER. LES ENFANTS, LESVÊTEMENTS, LES MEUBLES, L’ESSENCE ETAUTRES LIQUIDES QUI ÉMETTENT DES GAZVOLATILS INFLAMMABLES DOIVENTÊTRE TENUS ELOIGNÉS DE L’APPAREIL.SAMPLE |
Related manuals for Napoleon BL36NTE-1
Napoleon BL36NTE Installation And Operating Instructions Manual
Napoleon BL36NTE Installation And Operating Instructions Manual
Napoleon NEFL B-1 Installation And Operation Manual
Napoleon S20-1 Installation And Operation Manual
Napoleon B30NTR-1 Installation And Operation Manual
Napoleon B46NTRE Installation And Operation Manual
Napoleon B35NT Installation And Operation Manual
Napoleon B36PTREA-1 Installation And Operation Manual
Napoleon NEFL50B-1 Installation And Operation Manual
Napoleon NEFL60B-1 Installation And Operation Manual
manualsdatabase
Your AI-powered manual search engine