Safetyinformation Introduction ProductInformationSystemdesignMechanicalInstallationElectricalInstallationGettingstarted Optimization Parameters TechnicaldataComponentsizing Diagnostics ULInformationUnidrive M Regen Design Guide 303Issue Number: 410.5 Electromagnetic compatibility (EMC)This is a summary of the EMC performance of the drive. For full details, refer to the EMC Data Sheet which can be obtained from the supplier of thedrive.Table 10-42 Immunity complianceIEC 61800-3:2004 and EN 61800-3:2004+A1:2012The 2004 revision of the standard uses different terminology to align the requirements of the standard better with the EC EMC Directive.Power drive systems are categorized C1 to C4:Note that category 4 is more restrictive than E2R, since the rated current of the PDS must exceed 400 A or the supply voltage exceed 1000 V, for thecomplete PDS.Standard Type of immunity Test specification Application LevelIEC 61000-4-2EN 61000-4-2:2009 Electrostatic discharge 6 kV contact discharge8 kV air discharge Module enclosure Level 3(industrial)IEC 61000-4-3EN 61000-4-3:2006+A2:2010Radio frequency radiatedfield10 V/m prior to modulation80 - 1000 MHz80 % AM (1 kHz) modulationModule enclosure Level 3(industrial)IEC 61000-4-4EN 61000-4-4:2012 Fast transient burst5/50 ns 2 kV transient at 5 kHzrepetition frequency via coupling clamp Control lines Level 4(industrial harsh)5/50 ns 2 kV transient at 5 kHzrepetition frequency by direct injection Power lines Level 3(industrial)IEC 61000-4-5EN 61000-4-5:2014 SurgesCommon mode 4 kV1.2/50 ms waveshapeAC supply lines:line to ground Level 4Differential mode2 kV1.2/50 ms waveshapeAC supply lines:line to line Level 3Lines to ground Signal ports to ground 1 Level 2IEC 61000-4-6EN 61000-4-6:2014Conducted radiofrequency10V prior to modulation0.15 - 80 MHz80 % AM (1 kHz) modulationControl and power lines Level 3(industrial)IEC 61000-4-11EN 61000-4-11:2004Voltage dips andinterruptions-30 % 10 ms+60 % 100 ms-60 % 1 s<-95 % 5 sAC power portsIEC 61000-6-1EN 61000-6-1:2007Generic immunity standard for the residential, commercial and light- industrial environment CompliesIEC 61000-6-2EN 61000-6-2:2005 Generic immunity standard for the industrial environment CompliesIEC 61800-3EN 61800-3:2004+A1:2012Product standard for adjustable speed power drive systems(immunity requirements)Meets immunity requirements for first andsecond environmentsCategory Definition Corresponding code used aboveC1 Intended for use in the first or second environments RC2 Not a plug-in or movable device, and intended for use in the first environment onlywhen installed by a professional, or in the second environment IC3 Intended for use in the second environment, not the first environment E2UC4 Intended for use in the second environment in a system rated at over 400A, or in acomplex system. E2R