Lumina 40 Silos and ingredients136. Silos and ingredientsIn the silos and ingredient menu enter the basic data of the silo(s) and feed ingredients used.Installer SILO/INGRED.6.1 Tab page SiloInstaller SILO/INGRED. SILOS. tab page SiloDescription Setting of the name of the function.Maximum silo content Setting of the maximum silo content ( kilograms).Silo relay address Setting of the address of the digital output (relay) of the outgoing silo auger.The value between brackets (OFF)/(ON) indicates the actual auger status.Min. sensor Setting of the digital input address for empty silo detection.After flow after switch off Readout of the after flow value.The after flow does not need to be set: the control computer automatically calculatesthis. The after flow can be set to zero (0), the after flow will then be recalculated duringthe next following dosing in session. The after flow will be corrected to the new value inone go.Capacity kg/minute Setting of the amount of ingredient that can be dosed out in one minute.