Instruction manualOCM Pro CFpage 70 OCM Pro CF - Rev. 09 as of 07.06.2016®9 Parameter Setting9.1 Setting BasicsThe transmitter in the background operates with the settings which have beenentered at the beginning of the parameter setting. Just after you finish the newentries, the system asks to accept the new values.If “yes”, it is needed to enter the PIN code.2718 If prompted enter this number into the OCM Pro.Important NoteThe PIN code protects against unauthorized access.Never give the PIN code to any unauthorised persons. Even do not leave thecode next to the equipment or write it down on it.If a faulty code has been entered three times the parameter mode will be abort-ed. The unit will proceed to operate using the values set earlier. If the correctcode has been entered the modified parameters are accepted and the systemresets. This reset will take approx. 20-30 seconds.Besides having the option to save modified parameters or to reject any modifica-tion by pressing >No< at the end of the parameter setting procedure, it is possi-ble to jump back to the previous level using the >Back< function. This enablesthe user to modify settings which might have been forgotten without the need tobuffer previously modified settings.Fig. 9-1 Screen at end of parameter settingIf parameter settings are not going to be modified but just verified by selectingeach parameter, there will be no request at the end of the dialog.Modifications concerning language, units, contrast and display brightness do notrequire the PIN code as these settings influence just the way of representationand not measurement or the output of measurement values.