Installation3-6 1998 Nordson CorporationAll rights reserved106 588DIssued 8/98Manual 1-12NOTE: Use only Nordson or equivalent PTFE hoses with electricalcontinuity between the fittings. Hoses must be capable of withstanding amaximum working pressure of 220 bar (3200 psi). Do not use pipe in ahigh-pressure circuit. As an alternative, use seamless steel tubing,9.5-mm x 0.87-mm wall (3/8-in. x 0.035-in. wall).Figure 3-2 illustrates a typical heated circulating system with a spraydevice. Non-circulating systems are usually unheated systems.1. Connect the circulation valve kit to the siphon housing port (16).2. Connect the siphon rod and strainer (1) to a hose.3. Connect the return line to the circulation valve (4).4. Connect a fluid hose to the fluid outlet port (15).5. Connect both fluid hoses to the spray device (5).1. Connect the siphon hose (17) to the siphon housing port (16).2. Connect the siphon rod and strainer (1) to the siphon hose (17).3. Connect the fluid hose to the fluid outlet port (15).NOTE: Refer to the Packing Gland and Solvent Chamber Fluid Guide inthe Specifications section for additional solvent chamber fluid information.Fill the solvent chamber with the proper solvent chamber fluid. Refer tothe Maintenance section for procedures.4. Fluid ConnectionsCirculating SystemNon-Circulating System5. Solvent Chamber Fluids