Repair 7-11 1999 Nordson CorporationAll rights reserved 107 962HIssued 11/99Manual 21-19b. Warm a syringe (2) of dielectric grease to about 37−43 C(98−110 F) by holding it in your hands or running the syringeunder warm water.c. Insert the flexible tube (3) of the syringe into the electrostaticcable port on the cable adapter.NOTE: The end of the cable acts as a piston in the insulating tube (4),pushing the dielectric grease (1) around the resistor and spring (5), andaround the exterior of the tube. This totally covers the high-voltagecontact points inside the gun with dielectric grease.d. Apply about 1.5 cc of warmed grease into the electrostatic cableport.e. Install the insulating tube (4), resistor-end first (6), into the gunextension.9. See Figure 7-3. Install the air valve needle (2) and the trigger stopneedle (7).10. See Figure 7-2. Install the valve seat (34), and then carefully installthe air valve needle (22), the spring (16), and the retainer gasket (14).1. See Figure 7-2. Carefully screw the air valve plug (15) into the gunhandle (17).2. See Figure 7-3. Install the retaining ring (8) on the trigger stopneedle (7), and then tighten the rear-most set screw (9) on theright-hand side of the gun handle (4).CAUTION: Securely tighten the fluid tip on the gun extensionor it will leak fluid into the air passages, causing the charge toground out through the gun body.3. See Figure 7-2. Install the fluid tip (2) on the gun using the Nordsonwrench. Tighten the fluid tip hand-tight, and then tighten furtherwith 1/4−1/2 turn of the wrench.4. Install the air cap (1) and the retaining ring (3).5. Lubricate the O-rings (10) and install them into the grooves aroundthe horn and atomizing air passages in the gun handle (17).External Parts