Operation 5-5Part 1614575-01 2019 Nordson CorporationPresetsSee Figure 5-2. The preset select button allows the operator to quicklychange spray settings simply by changing the preset number. The operatorcan program the electrostatic and powder flow setpoints for a particular partor application..Up to 99 presets can be programmed. The system is shipped with presets1-3 are programmed at the factory for the most common applications.Presets 4 to 99 can be programmed as needed.See Table 5-3 and Table 5-4 for default presets values for the HD andVenturi systems.Table 5-3 HD System Factory PresetsPreset Electrostatics, Powder Flow kV A %1 Max kV, 150 g/min (20 lb/hr) 100 30 35 0.72 Max kV, 300 g/min (40 lb/hr) 100 30 80 1.03 Select Charge 3 (deep recess), 150 g/min (20 lb/hr) 100* 60* 35 0.7* Select Charge Mode settings are factory set and cannot be changed.Table 5-4 VT System Factory PresetsPreset Electrostatics, Powder Flow kV A1 Max kV, 150 g/min (20 lb/hr) 100 30 1.25 1.752 Max kV, 300 g/min (40 lb/hr) 100 30 2.25 0.753 Select Charge 3 (deep recess), 150 g/min (20 lb/hr) 100* 60* 1.25 1.75* Select Charge Mode settings are factory set and cannot be changed.