Operation5-10Part 1614575-01 2019 Nordson CorporationClassic ModeClassic Mode allows the user to control kV (STD) output or μA (AFC)output, but not both at the same time. The STD or AFC LEDs will light toindicate which mode is active.Refer to F03=01 in the Function Settings on page 4-7 for configuringcontroller to Custom mode.Adjust kV: Classic Mode: Standard (STD)Use the Classic Standard mode to adjust and set kV. μA cannot beadjusted in standard mode.1. To adjust the kV setpoint, press the kV button. The button LED lights toshow that kV is selected.2. Turn the Rotary Knob to increase or decrease the kV setpoint.3. Once the value is chosen the user can either: wait 3 seconds and the value will save for the current jobOR press Enter to also save the new value to the current preset.Electrostatic Display:Refer to View A. When the gun is not triggered the kV setpoint is displayed.Refer to View B. When the gun is triggered the actual kV and μA outputsare displayed.Gun Not TriggeredkV Setpoint DisplaysGun TriggeredActual kV & μA Output DisplaysView A View BAFCuASTDKVAFCuASTDKVFigure 5-4 Classic Mode (STD) − Electrostatic Displays