Advanced Features6-6Part 1614575-01 2019 Nordson CorporationManual iFlow PairingManual iFlow pairing is only done if the original programmed serial numberbecomes corrupt, which will display as Help code H54. Use the followingprocedure to manually pair the iFlow module to its respective spray gunmodule.NOTE: H54 may also be a result of a serial number improperly entered or aCAN network cable issue. Verify the serial number and check cable beforeproceeding with the manual pairing procedure.1. The serial number for F38 must be set to the following so the pairingprocess will be skipped:Function Display Serial Number Line DisplayLine 1, set to __00_Line 2, set to _000002. Remove power from the system and refer to iFlow Module on page 7-3of the Repair section for disassembly instructions.3. See Figure 6-3. Locate the SW1 and SW2 switches on the iFlowmodule board. Refer to Table 6-3 for definition of each SW1 position.4. Place SW1-3 in the Down position to activate override mode.5. Use the SW1 and SW2 to set the applicable gun number address. Manual Spray Guns − Adjust SW2 dial to gun number. Automatic Spray Guns − Configure SW1-1 and SW1-2 for theappropriate gun range listed in Table 6-4 and adjust SW2 dial toapplicable gun number.NOTE: When advancing to the next range of numbers, SW2-1represents the first number in that range. See Figure 6-4 for example ofconfigured address of iFlow module.PD21348Figure 6-3 Location of Switches