Operation4-26Part 1604870-05 2018 Nordson CorporationHD System ShutdownFor HD systems, complete the following steps:NOTE: Always remove the pickup tube from the powder source and placeinto an appropriate collector before pressing the color change button.NOTE: Before starting the purge cycle, make sure the guns are aimed intothe booth.1. For HD systems, press the Color Change button to start cleaning thesystem of residual powder.2. Purge the spray gun by pressing the Purge button on back of spray gununtil no more powder is blown from the gun.3. Press the Standby button to turn off the spray gun and interface.4. Turn off the system air supply and relieve the system air pressure at thepump cabinet.5. If shutting down for the night or a longer period of time, shut off systempower.6. Perform the Maintenance procedures on page 4-27.XT System ShutdownFor XT systems, complete the following steps:NOTE: Before starting the purge cycle, make sure the guns are aimed intothe booth.1. Purge the spray gun by pressing the Purge button until no more powderis blown from the gun.2. Press the Standby button to turn off the spray gun and interface.3. Turn off the system air supply and relieve the system air pressure.4. If shutting down for the night or a longer period of time, move the powerunit switch to the OFF position to shut off system power.5. Perform the Maintenance procedures on page 4-27.