Operation4-8Part 1604870-05 2018 Nordson CorporationEncore Nano Feedback Control Mode (NFC)To configure the controller for the NFC function, set the Electrostatic Control(F03) to the Custom mode (Custom= 00).Use the NFC mode to adjust and set both kV and μA in lower value range.See Function Settings on Controller Configuration section on page 4-20.A NFC Range and SettingsNFC mode allows the user to adjust the μA setting in increments of 0.1 μAbelow the value of 10.0 μA.For example, the user can set the μA settings from 12, 11, 10, 9.9, 9.8, 9.7,….. through 0.1.kV NFC Range and SettingsNFC mode allows the user to adjust the kV setting in increments of 1 kVbelow the value of 25 kV.For example, the user can set the kV settings from 25, 24, 23, 22, …..through 0.Classic ModeClassic Mode allows you to control kV (STD) output or μA (AFC) output,but not both at the same time.NOTE: To use Classic mode, the controller must be configured underfunction setting F03. Refer to Controller Configuration on page 4-20.Adjust kV: Classic Mode: Standard (STD)NOTE: Use the Classic Standard mode to adjust and set kV. μA cannot beadjusted in standard mode.1. To adjust the kV setpoint, press the kV button. The button LED lights toshow that kV is selected.2. Turn the Rotary Knob to increase or decrease the kV setpoint. Thesetpoint automatically saves in 3 seconds or when any button ispressed.