System Setup 3-17Part 1604857-04 2014 Nordson CorporationFunction SettingsTo change functions, press the Plus or Minus buttons on the kV/A panel.To change function values press the Plus or Minus buttons on the Flow Airpanel.Function No. Name Settings Default1 Gun Type 0 = Encore 02 Fluidizing 0 = Hopper, 1 = Box, 3 = Disable 03 Electrostatic Control 0 = Custom, 1 = Classic, 2 = NFC 04 Powder Flow Control 0 = Smart, 1 = Classic 05 Cable Length 0 = 6 meters, 1 = 12 meters, 2 = 18 meters 06 Vibratory Box Delay on, 0−90 seconds 30NOTE: Refer to the Operation section for explanations of the differences inElectrostatic Control and Powder Flow Control modes.Vibratory Box Feeder SettingsContinuous OperationTo set the vibrator motor to continuous operation, choose the “on” setting. Inthis mode, the vibrator motor turns on when the gun is first triggered andstays on until you press the Enable/Disable button or turn off system power.Shut Off DelayIf you set a delay time, the vibrator motor turns on when the gun is triggeredand stays on for the delay time after the trigger is released. This setting isdesigned to prevent chattering (rapid on/off cycling) of the vibrator motorduring production and extends the life of the motor. Adjust the delay asrequired for your application.Exiting Configuration ModeTo accept all function values and exit Configuration Mode, press theEnable/Disable button. The controller can now be operated normally.