Operation 4-3Part 1604857-04 2014 Nordson CorporationRe-Coat Metallics Deep RecessesFigure 4-2 Select Charge ModesNOTE: If you press the STD/AFC selection button while using a SelectCharge mode, the controller switches to Classic or Custom mode.Custom Electrostatic ModeCustom Mode is the factory default electrostatic mode.In Custom mode, both kV output and microampere A) output limits can beadjusted independently. Both the kV and AFC LEDs light to indicate that thecontroller is in this mode.Use the View button to toggle the display between kV and A. Pressthe + or − buttons to select the desired setpoints. The longer a button ispressed the faster the units change. The valid AFC range is 5−100 A. The valid STD range is 0 or 25−100 kV.Classic Electrostatic ModeClassic Mode is the optional electrostatic mode. The controller must beconfigured to use this mode; refer to page 3-16 for configurationinstructions.In Classic mode you can choose to control kV (STD) output or A (AFC)output, but not both at the same time.Classic Standard (STD) ModeSee Figure 4-3. Use the STD mode to set the no-load output voltage (kV).1. Press the STD/AFC button to toggle between STD and AFC.The LEDs light to show which is selected. Select STD. The STD LEDwill light.2. Press the View button to toggle the display between kV and A.Press the + or − buttons to select the desired kV setpoint. The longer abutton is pressed the faster the units change.The valid STD range is 0 or 25−100 kV.