16 6-050700 X2212iLW & 242iLW Standalone KeypadInstallation & Programming Manual7. ProgrammingTo enter program mode, press 99 # Master Code ✱. The yellowLED must then start blinking slowing (if not verify the master code iscorrect – refer to Section 9). The default Master Code is 1234.NOTE: If auto-entry is enabled, the ✱ (asterisk) key is not used toenter Program mode.To change the Master Code, enter:1 # new Master Code ✱ new Master Code ✱(When finished press the ✱ to exit program mode.)Note: Refer to Section 7.4 for adding user codes7.1 Programming OrderTo ensure that the keypad is programmed properly in the initialinstallation, program the keypad in the following order:● Step 1: Assigning Virtual Outputs to Physical Outputs● Step 2: Programming Output Time Durations● Step 3: Programming Users● Step 4: Programming Keypad Options7.2 Assigning Virtual Outputs to Physical OutputsThe keypad is equipped with both Virtual Outputs and PhysicalOutputs. Virtual Outputs are functions that you can assign to operateany Physical Output. Physical Outputs include the main relay, thethree relays on the aux relay board, and the two audio alerts.The 242 model has six physical outputs (four relays and two audioalerts). The 212 model has three physical outputs (a main relay andtwo audio alerts).● Using Command 10, you can assign any Virtual Output to anyPhysical Output or disable a Physical Output.● Each Physical Output can only have one Virtual Output assignedto it.