6-050700 X2 23212iLW & 242iLW Standalone KeypadInstallation & Programming Manual7.5 Programming Keypad OptionsCommand/Action Keys to Enter/DetailsCommand 30.Enable/DisableKeypad Options30 # option # enable/disable # ✱ ✱Option Disable Enable0 – Audio Keypress Feedback 0 = disabled 1 = ENABLED1 – Visual Keypress Feedback 0 = disabled 1 = ENABLED2 – Auto Entry 0 = DISABLED 1 = enabled3 – Error Lockout 0 = disabled 1 = ENABLED4 – User Lockout 0 = disabled 1 = ENABLED5 – Two-Part Users 0 = disabled 1 = ENABLED6 – Keypad Illumination 0 = disabled 1 = ENABLED7 – Keypad Dimming 0 = disabled 1 = ENABLED8 – REX Operation 0 = only whendoor loop closed1 = ALWAYSAuto EntryWhen auto-entry is enabled, users with codes thesame length as the master code do not have to pressthe ✱ key after entering their code. If you have a codegreater than the master code, you can use Auto-EntrySuspend. Just enter the # key prior to your codefollowed by the ✱ key.Example: # 23456 ✱ if the master code is four digits.Error LockoutWhen enabled, the keypad keeps track of the numberof consecutive invalid codes entered, includingattempts to access program mode. When thethreshold is reached, the yellow LED turns on solidand the keypad no longer responds to key pressesfor the programmed time duration. The count is resetby entering a valid code, including entering programmode. The error lockout threshold and duration isprogrammed with Command 32.Keypad Illumination Keypad backlighting can be enabled or disabled.Keypad DimmingWhen enabled, the backlighting illumination leveldecreases 15 seconds after the last key press. Whendisabled, the backlighting remains at full illuminationat all times.Command 40.Reset Defaults Only40 # 00000 # 00000 # ✱ ✱ (master code, allkeypad options and parameters)Command 46.Erase Users andReset DefaultSettings.46 # 00000 # 00000 # ✱ ✱