4 6-050700 X2212iLW & 242iLW Standalone KeypadInstallation & Programming Manual2. SpecificationsParameter Range/DescriptionVoltage 10–30 VDC, 12-24 VAC (Auto-Adjusting)Current93 mA @ 10 VDC; 158 mA @ 30 VDC,148 mA @ 12 VAC; 198 mA @ 24 VAC242 Model - Add 25 mA for each energized auxrelay (max = 75 mA)Environment For Indoor and Outdoor UseTemperature Tolerance -20° F to 130° F (-28° C to 54° C)Dimensions 5-1/8" H x 3-3/8" W x 5/8" DMain Relay (Form C) Contact Rating: 2 A @ 30 VAC/DCAux Relay (Form C) Contact Rating: 1 A @ 24 VAC/DCREX Input Normally Open Dry ContactDoor Position Input Normally Closed Dry ContactLEDs Bi-Color Red/Green; YellowDefault Keypad SettingsParameter Default SettingMaster Code 1234Lock Output Relay 1 (Main relay – 212 and 242)Alarm Shunt Output Relay 2 (242)Propped Door Output Relay 3 (242)Forced Door Output Relay 4 (242)Audio Alerts Not Assigned (212 and 242)REX Triggers Lock OutputREX Operation Always Triggers (regardless of Door Loop)Error Lockout EnabledError Lockout Threshold 3 AttemptsError Lockout Duration 10 SecondsLock Output Time 5 SecondsPropped Door Output Time 30 SecondsForced Door Output Time 10 SecondsVisual Keypress Feedback EnabledAudio Keypress Feedback EnabledAuto-Entry DisabledUser Lockout Enabled