Replacing the RAID card 105Result: The system boots up to the original configuration beforethe PEP installation.7 When the system is fully booted, open the Windows MegaRAIDconsole and rebuild the failed drive using the same processdescribed in "To synchronize the RAID after a successful PEPinstallation" (page 103).Result: The system is now in the original configuration.—End—Replacing the RAID cardThe RAID card is in low-profile slot 1 (counting from the top down) of thePCI riser assembly.CAUTIONRisk of electrical damage• Wear an antistatic ESD wrist strap when handling cardsor boards, or when working inside the server.• Do not touch the components or gold-edge connectorsof cards or boards.• Place the card on an antistatic surface until you areready to install it.PCI add-in cards are not hot-swappable. You must power down the systemand remove the power cords before replacing the card.CAUTIONRisk of physical equipment damageRemove the 1005r from the rack, and place it on a solid surfacewhen replacing or adding cards. The PCI riser assembly requiresconsiderable force when inserting it into the connector, andphysical damage can result if the assembly is not properly aligned.Placing the server on a solid surface such as a workbench givesyou a better view of the card alignment and lets you exert thenecessary force when inserting the assembly into the connector.Requirements• Phillips (cross head) screwdriver, #1 and #2 bit• RAID card replacement kitNortel CallPilot1005r Server Maintenance and DiagnosticsNN44200-704 01.06 Standard5.0 19 July 2007Copyright © 2007, Nortel Networks.