2IMPORTANT SAFETY INSTRUCTIONSCAUTION READ AND SAVE THESE INSTRUCTIONSAfter unpacking your table, inspect it thoroughly for damage. If you suspect a problem do not use the table andcall our customer service department at 800-916-4612.Improper use of this device can cause injury. Be sure to read all operating instructions prior to use.IMPORTANT - If the Foot Control is ordered, you must install a Foot Control Cradle per Installation Instruction partnumber MMINMD0008-EN.Weight limit (patient and accessories): 227 kg / 500 lbs. distributed evenly. (Bariatric Table only: 340 kg / 750 lbs.)Do not sit beyond warning line on carbon fiber top. On Lithotripsy / Urology Top - Do not sit on any extensions(Weight Limit: 200 lbs. / 91 kg.)The table utilizes four locking casters to permit movement of the table within the imaging suite. Accidental move-ment of the table may occur. Lock casters prior to accomplishing imaging of the patient. Lock casters when thepatient is mounting & dismounting the table.The table should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary,the table should be observed to verify normal operation in the configuration in which it will be used.The use of Accessories, transducers, and cables other than those specified (with the exception of transducers and cablessold by the Manufacturer of this device as replacement parts for internal components) may result in increased Emissionsor decreased Immunity of the table.The table is designed to be a standalone table used with radiographic equipment. This table must not be modified orincorporated into any other equipment.There may be pinch points under the table top. Do not have any body part under the top when the table is inmotion.Be certain that the table is completely lowered prior to discharging an ambulatory patient. The patient may lose balanceand fall. NOTE: The CFPMFXH is a fixed height table. It is recommended that all patients are assisted onto the table(physical assistance & step stools with side rails is recommended.)Patient must be secured with Safety Restraint Strap prior to using the tables.Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put intoservice according to the EMC information provided in the specifications at the end of this manual. (ExcludingCFPMFXH)Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment. (ExcludingCFPMFXH)This table is not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide.Electrical Shock Hazard. (Excluding CFPMFXH) The power supply/control module is located inside the liftingcolumn and under the top. No user serviceable parts are inside. Refer servicing to qualified personnel. Unplug wallconnector prior to contact with any cables connected to the power supply.To avoid the risk of electric shock, this equipment must only be connected an outlet this is properly grounded. SeeGROUNDING instructions in this manual.Grounding reliability can only be achieved when this equipment is connected to an equivalent 3 prong receptaclemarked “Hospital Only” or “Hospital Grade”.Oakworks medical tables are designed and built to provide many years of dependable service. Please follow localregulations and laws when disposing of the electrical components used in this table.I M P O R T A N T S A F E T Y I N S T R U C T I O N S