43856301TH Rev.3 110 /Oki Data CONFIDENTIAL 5. Maintenance Menu5.3.1.9 Number of print copies counter displayThis self-diagnostic menu is used to display status of the number of copies of a printer.1. Enter the ordinary self-diagnostic mode and press the MENU+, MENU- key until"PRINTER STATUS" is displayed in the display area. (Pressing the MENU+ keyincrements the test item and pressing the MENU- key decrements the test item.)2. When the MENU+, MENU- key is pressed, statuses of the number of printcopies are displayed in order.(Pressing the ONLINE or CANCEL key is invalid.)3. Pressing the BACK key terminates the test. (Returns to the status of step 1.)Display area,upper rowDisplay area,lower row Format Unit DetailsK-IMPRESSIONS ********IMAGES DEC Images Number of print copies of therespective colors are displayed.Y-IMPRESSIONS ********IMAGES DEC ImagesM-IMPRESSIONS ********IMAGES DEC ImagesC-IMPRESSIONS ********IMAGES DEC ImagesTOTAL SHEETCNT ********COUNTS DEC Prints Total number of print copies aredisplayed.5.3.1.10 Switching between the Factory mode and the Shipping modeThis self-diagnostic menu item is used to switch between the Factory mode and theShipping mode.1. Enter the self-diagnostic mode (level 1) and keep pressing the [MENU+] or[MENU-] key until the following message is displayed.FACTORY MODE SET2. When the [ENTER] key is pressed, the following message is displayed. Keeppressing the [MENU+] or [MENU-] key until the target item (refer to the followingtable) is displayed.FACTORY MODESHIPPING MODE *3. While the desired item to set is being displayed, press the [ENTER] key thatenables selection of the setting values.4. While the desired setting value is being displayed, press the [ENTER] key forlong period (3 seconds) that registers the displayed value in EEPROM. (Returnsto the status of step 2.)5. Repeat steps 2 to 4 as required.6. Pressing the [BACK] key terminates the test. (Returns to the status of step 1.)Display Setting value FunctionFACTORYMODE FACTORY MODE Sets the Factory working mode (fuse cut invalidmode).SHIPPING MODE Releases the Factory working mode to make the fusecut function valid.FUSE INTACTNote:******* indicatesINTACT or BLOWN.BELT UNIT ****** Checks the fuse status of the transport belt unit.FUSE UNIT ****** Checks the fuse status of the fuser unit.K-ID UNIT ****** Checks the fuse status of the K-1D unit.Y-ID UNIT ****** Checks the fuse status of the Y-1D unit.M-ID UNIT ****** Checks the fuse status of the Y-1D unit.C-ID UNIT ****** Checks the fuse status of the C-1D unit.