45530603TH Rev.2 5-51Oki Data CONFIDENTIAL 5. MAINTENANCE MENUS5.3.2.13 Self-diagnostic function settingThe self-diagnostic function setting is used for enabling or disabling the error detection bysensors.The detection can be enabled or disabled temporarily for troubleshooting research. Allowingfor setting engine operation options for which expert knowledge is required to be handled.This self-diagnostic should be used carefully.Be sure to restore the default settings of used options of the self-diagnostic.1. Enter the self-diagnostic (Level1) mode and, until the following messageappears, press the MENU or MENU button.sensoR setting2. Press the OK button. The following message appears. Press the MENUor MENU button until the option intended (refer to the table shown below)appears.toneR sensoRenaBLe *3. The setting on the lower display can be selected by pressing the OK button.The MENU button displays the next setting and the MENU button displaysthe preceding setting.4. Press the OK button while the desired setting is on the display. The setting isstored in the EEPROM. The state is restored to the step 2.5. Repeat steps 2 through 4 when necessary.6. Press the BACK button to end the setting (except where not in the step 4) (thestate is restored to the step 1).SENSOR SETTING ItemsLCD Setting value Operation of the setting value DetailsTONERSENSORENABLE Enables detection. Enables or disables tonersensor operation.DISABLE Disables detection.WASTE TNRSNSENABLE Enables detection. Enables or disables the wastetoner sensorDISABLE Disables detection.BELT UNITCHECKENABLE Enables checking. Enables or disables beltinstallation checking operation.DISABLE Disables checking.ID UNITCHECKENABLE Enables checking. Enables or disables IDinstallation checking operation.DISABLE Disables checking.REGADJUSTERRORENABLE Stops Enables or disables the displayof errors in the auto color mis-registration correction controlDISABLE Does not stopDRUM OVERLIFEStop Does not extend the life duration Enables or disables the lifeextension processingCONTINUANVE Extends the life durationWR POINTREV00H FFH A correction value. Adds a correction value for thedefault writing point.Default is in hatched area.