45530603TH Rev.2 6-32Oki Data CONFIDENTIAL 6. REPLACEMENT OF PARTS6.2.43 Hopping-Unit(1) Remove the MPT-Unit.(Refer to section 6.2.28)(2) Remove the two screws(silver)(6mm) and remove the Cover-Side-R .(3) Remove the two screws(silver)(6mm) and remove the Cover-Guide-Tray-Assy .(4) Remove the four screws(silver)(6mm) and four Round-head screw(black)(6mm)and remove the Hopping-Unit .6.2.42 Connector-Assy-Fuser(1) Remove the Guide-Assy-Eject.(Refer to section 6.2.13)(2) Remove the two Round-head screws(black)(6mm) and remove the Frame-Duct-CL .(3) Remove the ten Round-head screws(black)(6mm) and remove the Plate-Side-LB.(4) Remove the two Round-head screws(black)(6mm) and two washer andremove the Connector-Assy-Fuser .